17.6 Data table
DHX 3.5-1
Trend
DHX 6-2 Trend DHX 8-2 Trend DHX 10-2 Trend DHX 12-2 Trend
DHX 12-2 Plus
DHX 15-2 Trend
DHX 15-2 Plus
Item no. 200067 203795 200068 200069 200070 (Trend)
200066 (Plus)
200071 (Trend)
202151 (Plus)
Electrical data
Phase (50/60 Hz) 1/N/GND 1/N/GND | 2/GND 1/N/GND | 2/GND 1/N/GND | 2/GND 1/N/GND | 2/GND 1/N/GND | 2/GND
Rated voltage 120 V 240 V 208 V 240 V 208 V 240 V 208 V 240 V 208 V 240 V 208 V
Rated output 3.5 kW 6.0 kW 4.5 kW 7.2 kW 5.4 kW 9.6 kW 7.2 kW 12.0 kW 9.0 kW 14.4 kW 10.8 kW
Amperage draw 29.2 A 25 A 21.7 A 30 A 26 A 40 A 34.6 A 50 A 43.3 A 60 A 52 A
Min. recommended circuit breaker size
1
30 A 25 A 25 A 30 A 30 A 40 A 35 A 50 A 50 A 60 A 60 A
Min recommended wire size
2
(copper) 10/2 AWG 10/2 AWG 10/2 AWG 10/2 AWG 10/2 AWG 8/2 AWG 8/2 AWG 8/2 AWG 8/2 AWG 6/2 AWG 6/2 AWG
Min. resistivity ρ15 ≥ 1100 Ω cm
Max. conductivity ı15 ≤ 910 μS/cm
Connections
Water connections ½˝ NPT
Application limits
Maximum permissible pressure 145 psi (1 MPa)
Maximum inlet temperature for reheating 131 °F (55 °C)
Maximum inlet temperature 149 °F (65 °C)
User selectable temperature range 68140 °F (20–60 °C)
Internal anti-scalding protection
temperature limiter values
100, 109, 122, 140 °F (38, 43, 50, 60 °C)
Hydraulic data
Minimum water flow to activate unit 0.264 gal (1.0 l/min)
Nominal water volume 0.07 gal (0.277 l)
Other
Type of installation Over-sink/under-sink
Protection class 1
Insulating block Glass-reinforced polyamide
Heating system Direct Coil
Cover and back panel Plastic
Color White
Dimensions
Height 14
1
/
8
˝ (360 mm)
Width 8˝ (202 mm)
Depth 4
5
/
16
˝ (109 mm)
Weights
Weight 5.5 lbs (2.5 kg)
DHX 3.5-1 Trend ships with a 0.5 gpm (1.9 l/min) pressure compensating flow-reducer/aerator that must be installed.
DHX 6-2 Trend ships with a 1.0 gpm (3.8 l/min) pressure compensating flow-reducer/aerator that must be installed.
1
Overcurrent protection sized at 100% of load. Tankless water heaters are considered a non-continuous load. Use only GFCI Class A circuit breakers.
2
Copper conductors with a temperature rating of 75 °C or greater must be used. Conductors should be sized to maintain a voltage drop of less than 3% under load.
These are our recommendations. Check local codes for compliance if necessary.