Infrared Broiler Conversion
IMPORTANT: The infrared broiler orifice must be changed from rear of range before unit is installed.
Locate bag labeled IR Broiler Orifice.
Remove nut securing 90 degree fitting and broiler tubing to rear of range.
Remove Orifice from 90 degree fitting and replace with orifice from bag labeled IR Broiler Orifice.
Reverse procedure as needed to reassemble.
Preparing for Top Surface Conversion
Remove all grates, burner bowls, grate supports, surface burner caps, griddle, grill grates and grill
grate supports.
NOTE: Some models may not be equipped with all parts mentioned above.
IMPORTANT: For models equipped with griddles, notice position of griddle temperature probe for
proper reinstallation. Failure to properly reinstall could result in damage to griddle temperature
probe.