20
www.factorybuysdirect.com
200234-01A
Ignitor Button
Control Knob
Figure 21 - Ignitor Button and Control
Knob Locations
8. Be sure the slide switch on the front of the
receiver box is in the ON position.
9. Turn control knob counterclockwise
to the ON position. The main burner
should light.
Note: If burner does not light, push the
slide switch on the receiver box to the OFF
position, then back to the ON position.
Note: Please wait one minute after shut-
ting off heater to allow the control valve
to reset before starting again.
10. Make sure heater screen is in place before
operating heater.
OPERATION
11. If heater will not operate, follow the instruc-
tions To Turn Off Gas To Appliance, and
call your service technical or gas supplier.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
WARNING: If input gas
type is NG, make sure NG pilot
burner ignites. If input gas type
is LP, make sure LP pilot burner
ignites.
Shutting Off Heater
Turn control knob clockwise to the
OFF position.
Shutting Off Burner Only (pilot
stays lit )
Turn control knob clockwise to the
PILOT position.
TO TURN OFF GAS TO APPLIANCE
Figure 22 - Pilot
(Back of pilot
shown for clarity)
Pilot Air
Inlet Hole
Natural Gas
Burner
Propane/LP
Gas Burner
Thermocouple
Pilot Air Inlet Hole
Ignitor
Electrode
1. Follow steps 1 through 7 under Lighting
Instructions, page 19.
2. With control knob in PILOT position, strike
match, and hold near pilot. Press in control
knob; pilot should light.
3. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
4. Make sure the heater screen is in place
before operating heater.
MANUAL LIGHTING PROCEDURE
THERMOSTATIC CONTROL OPERATION
The thermostatic control used on this model
differs from standard thermostats. Standard
thermostats simply turn the burner on and off.
The thermostat used on this heater senses the
room temperature. At times the room may ex-
ceed the set temperature. If so, the burner will
shut off. The burner will cycle back on when
room temperature drops below the set tem-
perature. The control knob can be set to any
comfort level between HIGH (5) and LOW (1).
Note: The thermostat sensing bulb measures
the temperature depending on housing con-
struction.