PERFORMANCE DATA SHEETS
Base Grille Water Filtration System Model WF-NLC250/NLC250
Testedand certified by NSF International againstANSI/NSF Standard
42 for the reduction of Chlorine (ClassI) Tasteand Odor and against
ANSI/NSF Standard 53 forthe reduction of Lead, Cysts andTurbidity.
Capacity: 250 Gallons (946 Liters)
Service Flow Rate: 0.5 GPM (189 L/min.) @60 psi.
Substance Reduction U.S. EPA Average Maximum Average Minimum % Average % NSF Test
Aesthetic Effects MCL Influent Effluent Effluent Reduction Reduction Number
Chlorine Taste/Odor N/A 1.9 mg/L N/A 0.04 mg/L N/A 97.9% 994707
Particulate N/A 610,000/mL* N/A 154/mL N/A 99.97% 994711
Contaminant U.S. EPA Average Maximum Average Minimum % Average % NSF Test
Reduction MCL Influent Effluent Effluent Reduction Reduction Number
Cyst 99.95%** 89,250/mL* 6/mL 2.3/mL 99.993% 99.997% 994710
Turbidity 0.5 NTU 29 NTU 0.1 NTU 0.09 NTU 99.5% 99.69% 994710
Lead: @pH 6.5 0.015 mg/L 0.16 mg/L*** 0.001 mg/L 0.001 mg/L 99.4% 99.4% 994708
Lead: @pH 8.5 0.015 mg/L 0.16 mg/L*** 0.002 mg/L 0.001 mg/L 98.8% 99.4% 994709
Base Grille Water Filtration System Model WF-LC4OO/LC400
Tested and certified by NSF International against ANSI/NSF Standard
42 for the reduction of Chlorine (Class I) Taste and Odor and against
ANSI/NSF Standard 53 for the reduction of Lead, Cysts and Turbidity.
Capacity: 400 Gallons (1514Liters)
Service Flow Rate: 0.5 GPM (189 L/min.) @60 psi.
Substance Reduction U.S. EPA Average Maximum Average Minimum % Average % NSF Test
Aesthetic Effects MCL Influent Effluent Effluent Reduction Reduction Number
Chlorine Taste/Odor N/A 2.0 mg/L N/A 0.04 mg/L N/A 98% 994707
Particulate N/A 610,000/mL* N/A 154/mL N/A 99% 994711
Contaminant U.S. EPA Average Maximum Average Minimum % Average % NSF Test _
Reduction MCL Influent Effluent Effluent Reduction Reduction Number _
Cyst 99.95%** 89,250/mL* 6/mL 2.3/mL 99.993% 99.997% 994710
Turbidity 0.5 NTU 29 NTU 0.12 NTU 0.09 NTU 99.59% 99.69% 994710 _
Lead: @pH 6.5 0.015 mg/L 0.16 mg/L*** 0.001 mg/L 0.001 mg/L 99.4% 99.4% 994708
Lead: @pH 8.5 0.015 mg/L 0.16 mg/L*** 0.002 mg/L 0.001 mg/L 98.8% 99.4% 994709
• It is essential that operational, maintenance, and filter • Refer to the front cover or "Assistance or Service" section for _
replacement requirements be carried out for the product to the Manufacturer's name, address and telephone number.
perform as advertised. • Refer to the "Warranty" section for the Manufacturer's limited
• Model WF-NLC250 Change cartridge at least every 6-9 warranty.
months. Use replacement cartridge NLC 250, part# 9902.
2002 suggested retail price of $39.95 U.S.A./S49.95 Canada.
Prices are subject to change without notice.
• Model WF-LC4OO The filter monitor system measures the
amount of water that passes through the filter and alerts you
to replace the filter. When 90% of the filter's rated life is used,
the filter indicator light changes from green to yellow. When
100% of the filter's rated life is used, the filter indicator light
changes from yellow to red, and it is recommended that you
replace the filter. Use replacement cartridge LC400,
part# 9902. 2002 suggested retail price of $39.95 U.S.A./
$49.95 Canada. Prices are subject to change without notice.
• The product is for cold water use only.
• Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system.
Application Guidelines/Water Supply Parameters
Water Supply City or Well
Water Pressure 30 - 120 psi (207 - 827 kPa)
Water Temperature 33° - 100°F (0,6° - 37,8 ° C)
Testrequirement is at least 100,000particles/ml of AC Fine TestDust. Cyst performance is Yoreduction basedon NSF Standard53. Test
+ O
requirement is 0.15 mg/L _ 10%.These contaminantsare not necessarily inyour water supply. Performancemay vary based on local water conditions.