9
Assembling
OPERATING INSTRUCTIONS
STEP 1:
Pull the spring-loaded collar of the wand back
to insert your choice of quick connect nozzle.
Release the collar and push the nozzle until-
the collar clicks.
CAUTION
High pressure in nozzle area.
Risk of injury caused by improperly locked
nozzle.
▄ Make sure you hear a "click" when inserting
the nozzle tip into the wand.
▄ Pull the nozzle to make sure it is seated
properly before operating your unit.
STEP 2:
Attach the high pressure hose to the trigger
gun. Make sure to screw the hose all the way
into the trigger gun.
CAUTION
Engine shipped without oil. Before starting
engine, fill with oil. Do not over-fill. Do not
run the engine with a high or low oil level as
this can cause engine damage.
If you have further questions regarding the
engine, please refer to the engine manual
included with the unit.
ASSEMBLY INSTRUCTIONS
Illustration 2:
Attach handle to the frame of the pressure washer.
Align holes, insert hexagonal bolts (K) and tighten
with knobs (E).
Illustration 3:
Insert hexagonal bolts (C) on the tank knobs (D).
Mount nozzle holder (F) as shown on the illustra-
tion, align holes, insert bolt (C) / knob (D) and
tighten.
Illustration 4:
Insert hexagonal bolts (C) on the tank knobs (D).
Mount tank (B) to the pressure washer frame, align
holes, insert bolt (C) / knob (D) and tighten.
Illustration 5:
Place detergent siphon hose into the detergent
tank hole of the back of the tank (B), insert until
the hose end rests on the bottom of the deepest
part of the tank.
Place other end of the detergent siphon hose into
the pump's chemical nipple. Make sure the hose
is securely attached.
Illustration 6:
Place quick connect nozzle kit (G) in the nozzle
holder.
Illustration 7:
Push wand (H) into trigger gun (I) and then thread
the connection.
Illustration 8:
Remove cap/dipstick from the engine and add
correct amount of oil. Be sure oil level is between
"FULL / MAX" and "ADD / MIN" marks on dipstick
with machine on level surface.
Place cap/dipstick back.
Illustration 9:
(For G 3500 QHT machine only) Remove white
plug from pump and place pump vent plug.
Loading ...
Loading ...
Loading ...