Installation and connection en
19
Directly into the open air
Route the exhaust air duct directly
into the open air via an exhaust air
pipe through an open window.
Example: pipe connection - inside
diameter = 100 mm, flexible pipe,
corrugated
Through a wall box into chimneys or
ventilation shafts
Notes
It is not permitted to connect the
exhaust air duct to chimneys
which are connected to gas or
coal-fired ovens/cookers or gas-
fired heating systems.
If the appliance is being
connected to a moisture-
insulated ventilation shaft the
reponsible chimney sweep must
be informed and the approval of
the local building department
(building supervision office) or
the owner of the building must be
obtained.
Caution!
Risk of poisoning
If other appliances are operated in
the room where the appliance is
installed or in adjoining rooms, e.g.
gas-fired heating systems, gas-fired
boilers, coal-fired ovens connected
to a chimney, or open fireplaces, a
vacuum may be created, leading to
waste gases being sucked back.
Note: In every case, have safe
operation confirmed by the
responsible chimney sweep, boiler
engineer, ventilation specialist, etc.
A = curved pipe (R = 300 mm) 7
B = straight piece (1.5 m) 18
C = curved pipe (R = 100 mm) 10
D = straight piece (0.5 m) 6
Total pressure loss 41