STEP5.Connectneutralgroundingwire
andtheneutralwire(whiteorcenter)
ofpowersupplycordunderthecenter
screwofterminalblock.
STEP6.Connecttheothertwoinsulated
wirestoouterterminalblockscrews.
STEP7.Connectthegroundingwire
(green)ofthepowersupplycordtothe
externalgroundingconductorscrew.
Securelytightenallelectricalconnections.
STEP8.Inserttabofterminalblockcover
intoslotofthedryerrearpanel.Secure
coverwithhold-downscrew.
Proceed with Installation on page 24.
External
ground
connector
Neutral wire
Center silver-colored (white)
terminal block screw////
/
/
/
Green wire
of power supply
cord or bare
copper wire
_-inch, U,L -listed
strain relief
Neutral grounding
wire (green/yellow)
4-Wire Connection with
Frame-Grounding Conductor