Performance Data Sheet
SmartWater Filtration System
MWF Cartridge
This system hasbeen testedaccordingto NSF/ANSI42/53forreductionof the substanceslisted below.
The concentrationof the indicated substancesin water entering thesystem was reducedto a concentration
less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI42/53.*
'100%safety factors built in for unmetered usage)
Parameter USEPA lnfluent
MCL Challeng. e Concen_cafion
Chlorin( -- 2.0 mg/L + ] 0%
T&O -- --
Paniculate:':* -- m l<_<t ] 0,(X)0p_ides/mI,
Stmldard No. 42: Aesthetic Effects
Ir_uent Effluent
Average Average Maximum
].96 rag/l, 0.06 mg/l, 0.] ] mg/l,
(1,400,000 #/mI, 58,833 #/mI, 150,(_)0 #/mI,
Standard No. 53: Health Effects
Parameter USEPA
MCL
] NT[
!)!).95% R(duction
99% Rc(/u(tion
0.015 mg/I,
0.015 mg/I,
0.002 mg/I,
0.002 rag/l,
0.002 rag/I,
0.0002 mg/L
"IinSidiw
(;ysls
Xsbestos
I,ead at pit 6.5
l _ead ai pH 8.5
,Me_vmy at pH 6.5
M(lvtll) at p}{ 8.5
Alachlor
[ Jll(/an(
2,44)
qbxaphenc
Bei3z(i3e
(]arl)oftl/'a//
1,4 dich/0r0benzene
Atrazin{
_fhlent
Challenge Concentration
]1 +1 NT['***
\'lininmm 50,000 I,
]07 to ](_sfibers/I,; > ]0pro
0.15 rag/I,_+ ] 0%
0.15 rag/I,_+ ] 0%
0.006 mg/L + 10%
0.006 mg/L + 1()!?i
0.04 rag/i, + ]0!?i
0.002 mg/L + ] ()!_i
0.070 mg/L
0.003 mg/L
0.001 mg/L
0.040 mg/L
0.075 rag/i,
0.003 mg/L
In[luent
Average
]0.5 NI'/'
] ]8,750 #/I,
57 MF/I,
0.1?)67rag/I,
0.1433 rag/I,
0.0059 rag/I,
0.0057 rag/I,
0.0367 rag/l,
0.0020 rag/I,
Effluent
Average Maximtml
0.14 NI'/' 0.28 NTL
< ] #/I, 4 #/I,
0.996 MF/L < ] \IF/I,
<0.001 */N/I, <0.001 rag/I,
< 0.001 mg/L < 0.001 rag/I,
0.000350 mg/L 0.0007 mg/L
0.000325 mg/L 0.0006 mg/L
0.00027, rag/I, 0.0004 mg/L
< 0.00002 rag/l, <0.00002 mg/L
0.210 rag/I, + ] ()!_ 0.2033 rag/I, 0.00337 rag/I,
0.015 rag/I, + ] ()!_i 0.0160 rag/I, 0.00100 rag/l,
0.015 mg/L + ] 0!_i 0.0145 rag/I, 0.000500 mg/L
0.0S) mg/L + 10!fi 0.0830 rag/I, 0.001000 mg/L
0.225 rag/L+ 10!_ 0.2283 rag/I, 0.000500 mg/L
0.009 mg/I,+ 10!_ 0.(_)87 rag/I, < 0.0(_)5 rag/I,
0.01 ]000 rag/I,
0.00] 000 rag/I,
0.000500 rag/I,
0.001000 rag/I,
0.000500 rag/I,
< 0.0005 rag/I,
% Reduction
Average _ttm
96.77% !)4.74%
99.14% !)7.97%
% Redudion
Average Minimum
98.54% 97.20%
> 99.99{i > 99.99%
99.60% 99.39%
9!).36% 99.2{)%
99.30% 99.2{)%
94.70% 87.50!_
93.20% 89.29%
99.34% {)8.67%
99.(_)% 98.95%
98.32% 94.50!_
93.44% 9] .67!_
96.51% !)5.83!_
98.78% 98.65!i
9{).78% 99.77%
94.22% 93.33%
Min. Required
Reducllon
>50%
>8-,%
Min. Reqtdred
Reduction
0.5 NI'/'
> 9{).{)5%
> 99%
0.010 rag/I,
0.010 mg/L
0.002 mg/L
0.002 mg/L
0.002 mg/L
0.0002 mg/L
0.070 mg/L
0.007, mg/L
0.005 mg/L
0.04 rag/I,
0.075 mg/L
0.00,'4mg/L
Tested usfl_ga flow rate of O.5Ogpm; pressure of 6O psig pH of 7,5_+0,5, temp, of 68%+ 5°F(20°_+3°C)
_ Measurement in Particles/ml. Particles used were 0.5-1 microns
..... NTU=Nephelometric Turbidity units
Operating Specifications
[] Capadt_ : certified tot up to 300 gallons (I 135 1); up to six months for models _dthout a repla(ement tilter indicator light;
up to one }ear for models with a replacement filter indicator light
[] Pressure requirement: 40-120 psi (2.8-8.2 bar), non-shock
[]Tempe_ mue 33 100 _ (0.6-38"(;)
[] Flow rate: 0.5 gpm ( 1.9 lpm)
General Installation/Operetion/Maintenance Requirements
[] Flush new cartridge, at hill flow ,*o_ 3 minutes to })m'ge, out trapped air.
[] Replace c'u'tridoe, _ _hen flo_ becomes too slo_.
Special Notices
[] Installation instructions, pai_s and serG(e a_ailabilit), and standard warrant) are included with the product when shipped.
[] This drinking _,_ater s}stem must be maintained aCCOl'diilg to mamdhctuier's illstrtlctiolls, including replacement of filter cartridges.
[] Do not use with water that is microbiologicall} tmsaie or of unknown qualit} without adequate disinfection before or
after the s}stem. S}stems certified for c}st reduction ma} be used on disinfected *_ater that max contain filterable cxsts.
[] The contaminants or other substances I'eIl/oved of reduced b} this water treatment sxstem are not necessaril} in xour water.
[] Check for compliance with the state and local laws and regulations.
[] Note that while the testing was performed under standard laborator} conditions, actual performance ma} Xr_'}. %stems must
be installed and operated in accordance with manuihcturer's recommended procedures and guidelines.
Standard No. 42: Aesthetic Effects
Chemical Lnit
Chlorine Taste m_d Odor
Methanital Filtration [nit
Particulate Reduction, Class I
System "[-est(d and Certified by NSF International against ANSI!NSF Standard 42 & 53 for the reduction of:
Standard No. 53: Health Effects
Chemical Reduction Unit
Alachlor and Atrazine Reduction
Benzene and (]arboflwan Reduction
1,4 dichl()robenzene and 2,44) Reduction
Lead and I_indane Reduction
Mercury and Toxaphene Reduction
Mechanical Fihration l nit
Turbidity Reduction
Cyst and Asbestos Re(luction
Manufhctuled tor: General Electric Compal_y, Louisville, KY 4(}225