13
Installation Instructions
WATER DRAINAGE
During dehumidifying modes, remove the upper drain plug from the
back of the unit, install the drain connector (5/8 in. universal female
connecter) with 3/4 in. hose (not included). For the models without
a drain connector, just attach the drain hose to the hole. Place the
open end of the hose directly over the drain area in your basement
fl oor.
NOTE: Make sure the hose is secure so there are no leaks. Direct
the hose toward the drain, making sure that there are no kinks that
will stop the water from fl owing. Place the end of the hose into the
drain and make sure the end of the hose is down to let the water fl ow
smoothly, never raise it.
When the water level of the bottom tray reaches a predetermined
level, the unit beeps 8 times, the digital display area shows P1. At this
time the air conditioning/dehumidifi cation process will immediately
stop. However, the fan motor will continue to operate (this is normal).
Carefully move the unit to a drain location, remove the bottom drain
plug and let the water drain away. Restart the machine until the P1
symbol disappears. If the error repeats, call for service.
NOTE: When operating or draining water, always protect carpeting or
fl oors from possible water spillage.
NOTE: Be sure to reinstall the bottom drain plug before using the unit.
Remove the
upper drain plug
Continuous
drain hose
Fig.20