Loading ...
Loading ...
Loading ...
Page 10
Operating
Instructions
Error codes:
AS - Room temperature sensor error -
Unplug the unit and plug it back in. If
error repeats, call for service.
NOTE: In Fan only mode, it will display
“LO” or “HI”.
ES - Evaporator temperature sensor error
- Unplug the unit and plug it back in.
If error repeats, call for service.
DISPLAYS:
Shows the set temperature in °C or °F.
While on Fan only mode, it shows the
room temperature.
Displayed in COOL mode
operation.
Displayed in FAN mode operation.
Displayed in ENERGY SAVER
mode operation.
Displayed in WiFi feature operation.
Displayed in CHECK FILTER mode
operation.
Displayed when room temperature
is lower than 0°C/32°F.
Displayed when room temperature
is higher than 37°C/99°F.
HI
L0
NOTE
If an operation has not been selected
within 10 seconds, the display will dim.
Display will light up again when an
operation is selected.
Wait 3 minutes before resuming
operation
After the unit has stopped, it can not
be restarted before 3 minutes. This
is to protect the unit. Operation will
automatically start after 3 minutes.
Auto Restart
If the unit turns off unexpectedly due
to a power cut, it will restart with the
previous function setting automatically
when the power resumes.
Auto Defrost
When frost builds up on the evaporator
coils, the compressor will cycle off and
the fan will continue to run until the frost
disappears.
Energy Saver feature
This function is available on COOL
automatically. The fan will continue to
run for 3 minutes after the compressor
shuts off. The fan then cycles on for
2 minutes at 10 minute intervals until
the room temperature is above the
set temperature, at which time the
compressor turns back on and Cooling
Starts.