MODELS MUA006A • MUA008A • MUA010A
Page 8
WIRE THE SYSTEM
BLACK (LINE)
WHITE (COMMON)
GREEN (GROUND)
MAKE-UP AIR DAMPER
TRANSFORMER
24V
PRESSURE
SWITCH
WIRING DIAGRAM
ONE DAMPER
24V
BLACK (LINE)
WHITE (COMMON)
GREEN (GROUND)
MAKE-UP AIR DAMPER
TRANSFORMER
24V
PRESSURE
SWITCH
WIRING DIAGRAM
MULTIPLE DAMPERS
MAKE-UP AIR DAMPER
24V 24V24V
TEST THE SYSTEM
Oncethedamper,pressureswitch,andprobeisinstalled.Tu r nontherangehoodtohighspeedandconfirmthatthedamperopens.
Turn off the hood and check to see if the damper closes.
A qualified HVAC contractor should also ensure the proper operation and venting of all combustion equipment in the home.
Wire the system as shown.
FALSE TRIPPING
Under certain extreme conditions there could be false tripping of the damper (opening when the range hood blower is off). If false tripping
is encountered, place an in-line backdraft damper (available from your local hardware store or from Zephyr) between the probe and the
roof or wall cap.
SERVICE PARTS
50500133 PressureSwitchKit
12110018 24V Transformer
54060012 6”MotorizedDamper
54060013 8”MotorizedDamper
54060014 10”MotorizedDamper
24V
20V
24V CONTACTS
TRANSFORMER WIRING