Installation Guidelines
•Whereawallorotherobstacleisinthepathofoutdoorunit’sinletoroutletairow,followtheinstallationguidelinesbelow.
•Foranyofthebelowinstallationpatterns,thewallheightontheoutletsideshouldbe47-1/4inch(1200mm)orless.
More than
3-15/16 (100)
More than
13-3/4 (350)
Side view
47-1/4
(1200)
or less
More than
1-15/16 (50)
More than
1-15/16 (50)
More than
13-3/4 (350)
Top view
More than
3-15/16 (100)
unit: inch (mm)
Wall facing one side Walls facing two sides
Top view
More than
3-15/16 (100)
More than
13-3/4 (350)
More than
1-15/16 (50)
Walls facing three sides
Outdoor Unit Installation
1. Installing outdoor unit
1)
Wheninstallingtheoutdoorunit,referto“PrecautionsforSelectingtheLocation”andthe“OutdoorUnitInstallationDrawings”.
2) Ifdrainworkisnecessary,followtheproceduresbelow.
2. Drain work
•Usedrainplugfordrainage.
•Ifthedrainportiscoveredbyamountingbaseoroorsurface,placeadditionalfootbasesofatleast3-15/16inch
(100mm)inheightundertheoutdoorunit’sfeet.
•Incoldareas,donotuseadrainsocket(A),draincaps(B)andadrainhosewiththeoutdoorunit.
(Otherwise,drainwatermayfreeze,impairingheatingperformance.)
1) Insertdrainreceiver(C)ontodrainsocket(A)anddraincap(B)beyond4
projectionsarounddrainsocketanddraincap.
2) Insertdrainsocketanddraincapsintotheirmatchingdrainhole;Drainsocket
(A)intodrainholeIanddraincaps(B)intotheotherdrainholes.After
insertion,turnthemabout40°clockwise.
Projections Projections
(C) Drain receiver
(A) Drain socket (B) Drain cap
I
(Besurenottoinsertthemintowrongdrain
holes,ortherecauseswaterleakage.)
(Viewfrombottom)
NOTE
Checkthatthedrainreceiver(C)iscorrectlyengagedwiththeprojectionsofthedrainsocket(A)anddraincap(B).
Otherwise,waterleakagemayresult.
Projections
(4 points)
Projections
(4 points)
3) Connectvinylhoseonthemarket(internaldiameterof1inch(25mm))todrainsocket(A).
(Ifthehoseistoolongandhangsdown,xitcarefullytopreventthekinks.)
4) MakesurethatthereisnowaterleakagefromportionI,II,orIII.
NOTE
Ifthedrainholesoftheoutdoorunitarecoveredwiththemountingbracketortheoor,raisetheunittoprovidethespaceof
morethan3-15/16inch(100mm)underthelegoftheoutdoorunit.