FUELING INSTRUCTIONS
This wood stove has been certied by the US EPA to
meet strict 2020 guidelines. To ensure this unit produces
the optimal minimum emissions it is critical that only
well-seasoned cordwood is burned (see the “Fuel
Recommendations” section of this manual). Burning
unseasoned wet wood only hurts your stoves eciency
and leads to accelerated creosote buildup in your chimney.
Be considerate of the environment and only burn dry wood.
CAUTION:
DO NOT LEAVE APPLIANCE UNATTENDED THE WITH
DOOR OPEN.
For a cold start-up, place 4 to 5 pieces of newspaper into
the rebox. On top of the newspaper, lay 4 lbs of kindling in
random placement to ensure airow through the kindling.
On top of the kindling, place approximately 7 lbs of small
pieces of cordwood. NOTE: Use smaller pieces of wood
during start-up and a high burn rate to increase the stove
temperature.
7 lb
Pull the air control out fully. Light the newspaper and
leave the door slightly open for about a minute. NOTE:
You may have to leave it open a bit longer, depending on
your chimney height and outdoor conditions. After about a
minute (or once your re is well started) close the door and
allow the kindling to ignite. Once the kindling has burned
down to a starter coal bed, load the unit with approximately
29 lbs of fuel for the rst high burn load.
29 lbs
HIGH
After the rst high burn load and the stove is well warmed
up, adjust the unit as needed for a medium or low burn
setting. For a medium burn, once the high burn fuel load
is burned down to an established coal bed, load the unit
with 34 lbs of cordwood and close the door immediately.
Leave the air control fully open (in the “HI” position) for
5 minutes. After 5 minutes push in the air control to the
medium position (midway between the “Low” and “Hi”
position).
34 lbs
For a low burn setting once the high burn (or medium) fuel
load is burned down to an established coal bed, load the unit
with 32 lbs of cordwood and close the door immediately.
Leave the air control fully open (in the “HI” position) for
4.5 minutes then close halfway. After 15 minutes begin to
push the air control in to the “Low” postion (air control fully
pushed in). NOTE: Do not close the air too quickly. Closing
the air too quickly will cause the unit to smoke.
32 lbs