SERVICING INSTRUCTIONS
ACCESS PANELS
Each warmer plate has a center stud which screws into a bracket.
Warmer plates on Canadian brewers are secured with a nut.
Remove button plug on bottom of brewer to access nut on main
warmer. Remove top panel to access nuts on top warmers.
Remove warmer plates by turning counter-clockwise.
Solenoid door is held by two screws and a retaining lip.
IN-LINE BREWERS:
Top panel is held by two screws at the rear and a retaining lip at
the front. Disconnect wires from the upper warmers.
Top front panel is held by two screws at the bottom and a
retaining lip at the top.
Bottom front panel is held by two clips under the warmer plate.
CAUTION:
SHOCK HAZARD
Opening access panels or
removing warmer plates on this
brew may expose uninsulated
electrical components.
Disconnect brewer from
electrical power before
removing any panel or warmer
plate.
Fig. 9 Access Panels
11
IL1621a
SOLENOID
DOOR
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer