Hood and cabinetry clearances (mm)
Type of gas used
Type of
burner
Injector
marketing
Nominal heat
flow kW
Rated
consumption
Reduced heat
capacity kW
Gas pressure mbar
min. nom. max.
NATURAL GAS
(Methane) G20
2 ring
Inner
125+71
71
6,00
0,80
571 l/h
76 l/h
1,50
0,30
17 20 25
rapid 125 3,00 286 l/h 0,70
semi-rapid 97 1,75 167 l/h 0,40
auxiliary 78 1,00 95 l/h 0,30
LIQUEFIED GAS
(Butane) G30
2 ring
Inner
80+46
46
6,00
0,80
436 g/h
58 g/h
1,50
0,30
20 28-30 35
rapid 85 3,00 218 g/h 0,70
semi-rapid 66 1,75 127 g/h 0,40
auxiliary 50 1,00 73 g/h 0,30
LIQUEFIED GAS
(Propane) G31
2 ring
Inner
80+46
46
6,00
0,80
429 g/h
57 g/h
1,50
0,30
25 37 45
rapid 85 3,00 214 g/h 0,70
semi-rapid 66 1,75 125 g/h 0,40
auxiliary 50 1,00 71 g/h 0,30
Type of gas used
Model configuration
5 burners 2C 4,8kW
Rated thermal flow rate kW Total rated consumption
Air required (m
3
) for burning
1 m
3
of gas
G20 20 mbar 2C-1R-2SR -1AUX 13,50 1286 l/h 9,52
G30 28-30 mbar 2C-1R-2SR -1AUX 13,50 981 g/h 30,94
G31 37 mbar 2C-1R-2SR -1AUX 13,50 964 g/h 23,80
Note: If the distance Abetween the
wall cupboards in the kitchen is between
600mm and 730mm, the height “B”
must be at least 530mm.
If the distance Abetween the wall
cupboards is greater than the width of
the hob, the height “B” must be at least
400 mm.
N.B. For the semi-flush mount version
t
he 1.5 mm milling is not necessary.
Injectors table
Category
II2H3+
Refer to the injector table of your Country.
Electric supply: 220-240 V ~ 50/60 Hz 0,6W
8
4
0
+
1
0
4
9
0
+
1
0
R
1
2
8
6
0
5
1
0
7
4
Loading ...
Loading ...
Loading ...