2b. Follow brewing instructions on page 11.
NOTE: To cancel brewing, simply press the
selected brew size once again and the brewing
process will be stopped.
Caution: There are two sharp needles in
the brewing chamber that puncture the
capsule, one above and one below. To avoid
risk of injury, do not put your fingers in the
brewing chamber.
3. After brewing, raise the handle and remove
the reusable coffee capsule. Use caution as
the reusable coffee capsule will be hot.
4. Replace the capsule holder, ensuring that the
arrow on capsule rim aligns with the arrow on
the brewing chamber. Gently push the capsule
holder to snap into place.
NOTE: This Coffeemaker is compatible with most
reusable coffee capsules.
SINGLE-SERVE
COFFEEMAKER
CLEANING AND
MAINTENANCE
CLEANING EXTERNAL PARTS
We recommend regular cleaning of the
Coffeemaker’s external components.
1. Never immerse the Coffeemaker in water or
other liquids. The housing and other external
components may be cleaned with a soapy,
damp, nonabrasive cloth.
2. To remove the drip tray, simply slide it toward
you, keeping it level at all times in order to
prevent spills. The drip tray and drip tray plate
are dishwasher safe. Do not clean drip tray
with cleansers, steel wool pads or other
abrasive materials.
CLEANING THE
CAPSULE HOLDER
Caution: There are sharp needles that
puncture the capsule above and below.
To avoid risk of injury, do not put your fingers
in the capsule brewing chamber.
1. The capsule holder is top-shelf dishwasher
safe (use low temperature cycle). To remove,
lift the handle to open the brewing chamber.
Grasp the top of the capsule holder and
pull up.
2. Cleaning the Funnel – To remove funnel from
capsule holder, hold funnel in left hand, twist
bottom away from you slightly and pull away
from capsule holder to remove. The funnel is
top-rack dishwasher safe.
NOTE: The funnel may be tight the first few
times you go to remove it; this is normal and
will loosen with continued use.
3. Cleaning the Exit Needle The exit needle is
located on the inside bottom of the capsule
holder assembly. Should a clog arise because
of coffee grounds, it can be cleaned using
a paper clip or similar tool. Remove capsule
holder from unit, then remove funnel from
capsule holder and insert the paper clip into
exit needle to loosen the clog and push it out.
Replace funnel onto capsule holder by
lining up tabs in funnel with notches on
capsule holder, twist toward you until it locks
into place. After cleaning, replace capsule
holder, being sure to align the arrow on the
capsule holder rim with arrow on the brewing
chamber.
4. Cleaning the Piercing Needle The piercing
needle is located on the inside of the brewing
chamber. Should a clog arise because of
coffee grounds, it can be cleaned using a
paper clip or similar tool. Insert paper clip
to loosen the clog and push it out.
NOTE: If the 6oz, 8oz and 10oz buttons are
flashing together, your unit has overheated. Please
follow the instructions above to clean the piercing
needle and resume use.