INSTALLATION
79
Burner Chart
ADJUSTMENT
Burner Injector Size (mm) NG consumption
@ 1kPa (MJ/h)
Injector
Size (mm)
ULPG consumption
@ 2.75kPa (MJ/h)
Dual Wok 1.75 / 0.80 17 1.10 / 0.50 20
Wok 1.9 18 1.12 18
Large 1.55 12.5 0.92 12.5
Medium 1.18 7.5 0.68 7
Fish 1.55 12.5 0.95 13
Tepanyaki Plate (medium
and large burner)
1.18, 1.55 7.5, 12.5 0.68, 0.92 7.0, 12.5
Simmer Plate (large) 1.55 12.5 0.92 12.5