PROBLEM POSSIBLE CAUSES SOLUTIONS
No sound
from button
press or
end of cycle
notification
The chime feature has been
muted
Press and hold the Wash Temp
button for 3 seconds to unmute
the chime (on some models). Once
unmuted, the sound from the button
press and end of cycle reminder will
both be restored.
Dryer runs
but won’t
heat
If 1 of the 2 fuses in the dryer
circuit is blown, the drum
may turn but the heater will
not operate (electric models).
Gas supply valve is not open
(gas models).
Dryer does not have enough
air supply to support the
burner flame (gas models).
LP gas supply tank is empty
or there has been a utility
interruption of natural gas
(gas models).
• Replace fuse.
Check to make sure supply valve is
open. See
Installation
section for
procedure.
• See
Installation
section.
Refill or replace tank. Dryer should
heat when utility service is restored.
Drying cycle
takes too
long
Outside of
the
dryer feels
too hot or
smells hot
Lint filter is clogged with lint.
Exhaust duct requirements
have not been met.
Electric dryer is connected to
a 208 volt circuit.
Drying procedures not
followed.
Outside exhaust hood or
exhaust duct may be clogged
or restricted.
• High humidity.
Make sure all lint has been removed
from the dryer lint filter before
starting each cycle.
Exhaust duct must be at least 4
inches in diameter and made of rigid
or semi-rigid metal.
When in place, the duct must have
no more than three 90° bends and
must not exceed length listed in
Installation
section.
Drying time will be 20% longer when
drying on a 208 volt circuit than
when drying on a 240 volt circuit.
See Operating Instructions.
Clean out any obstruction.
Use a dehumidifier near the dryer.