O
Performance Data Sheet For Filter Model 9000 077095
Using Replacement Cartridge 900(! 0771(/4
This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below
The concentration of the indicated substances in water entering the system was reduced to a concentration
less fllan or equal to the permissible limit for water leaving the system, as specified in NSF/ANS142 and 53
System tested and certified by NS F international in Model 9000 077095
against NSF/ANSI Standard 53 for the reduction of Cysts and Turbidily
and against Standard NSF/ANS142 for the reduction of Chlorine Taste and Odor;
Nominal Particulate Class 1.
Note that while tile testing was performed under standard
laboratory conditions, actual perlbrmance may vary
to a capacily of 739.68 gallons (2800 liters).
Substance
Cysts*
Turbidity
Average
_fluent
Concen_at_n
166500
10.7
Inlluent
Challenge
Concentration mg/L
Minimum 50,000/L
I 1 + 1 NTU
Product
Water
Concentration
1
0.3!
Average
%
Reduction
99.99
97.10
Maximum Permissible Max. Min. % NSF
Product Water Effluent Reduction Test
Concentratiou
99.95 1 99.99 511077-03
0.5 NTU 0.49 95.42 511078-03
Particulate
Class IParticle size: >05 to < 1 um 5700000 AI least !0,000 particles/mI
Chlorine taste and odor 1.9 2,0 rag/L_+ 10%
*Based on the use ofCryptosporium parvum oocysts
App h_araln e to rs
__a)
Iw_ o(r' E (0.6" C - 38" C)
[__ gpm (2.8_?pm)
30583
0.05
99.52
97.3
85% 69000 98.9 511079-03
_50% 0.06 96.84 511081-03
Systems must be installed and operated in accordance with
manufacturer's recommended procedures and guidelines
Change filter at least exery 6 - 9 months.
Flush new filter lbr 5 minutes
See warranty card tbr complete details
Do not use with water that is microbk)logica Uy unsalh or of unknown qualRy willluut adeqtiate disinlhction belbre or afler ihe system
Systems certified _r cyst reduct_n may be used on disinfected waters _at may contain lill_rab]e cysts.
Enttre Syslcm (excluding disposable caru'ldges) is warranaed lbr a period ofol_e year, Disposable carmdges arc
Warranned R)r delbcts in material and workmanship only Selxice lil_: of disposable filler cartridges valJes
with local water condlnons and is thus aot warranned
For estimated costs ofrephcen_ent
elements p]ease visl_ your loca I app]iance dealer
or parts distributor.
"rl
m_
m
O
Q_
CD
C
_a
i
I
O
_a
Q_
Q_
_a
O
Q_
m
O
Q_
C
O
O
Manulhcture d by:
Cuno Engineered Products
1000 Apollo Road
Eagan, iVIN55121-2240 U.S.A.