Questions, problems, missing parts?
Before returning to your retailer, call our customer service at 1-800-887-6326
Monday – Friday 9:00 a.m. – 5:00 p.m. CST
Sku Number: 351-8005
4LT CEILING LAMP
Model Number: C0093
PACKAGE CONTENTS
HARDWARE CONTENTS Note: Hardware not shown actual size.
Ball Nut
X2
Page 1 of 3
Green Grounding
Screw
X1
AA
CC
FF
EE
BB
Mounting Screw
X2
Wire Connector
X3
Hex Nut
X2
Mounting Strap
X1
Long Screw
X2
DD
GG
A
C
B
D
E

AA
CC
2
3. Pull out the source wires from
the
---Connect the hot wire (usually
black insulation)
from the fixture to
black wire from the power
---Connect the neutral wire (usually
white insulation) from the fixture
to the white wire from the power
source.
---Attach the fixture grounding wire
(usually
green insulation or bare wire) to the mounting
strap(AA) with the green grounding screw.
connect it to the house grounding wire with the
wire connector(EE).
Carefully put the wires back into the outlet box.
4.Attach the fixture to the mounting
strap(AA) by inserting the long
screws,
then secure it with two ball
5.
Before beginning assembly, installation or operation of product, make sure all parts are present. Compare parts with
package contents list and diagram on previous page. If any part is missing or damaged, do not attempt to assemble,
install or operate the product. Contact customer service for replacement parts.
Tools Required for Assembly (not included): Screwdriver, Phillips Screwdriver, Pliers, Electrical Tape, Wire Cutters,
Safety Glasses, Ladder, Wire Stripper.
Page 2 of 3
PREPARATION
ASSEMBLY INSTRUCTIONS
Turn off the power at fuse or circuit box.
Please read and understand this entire manual before attempting to assemble, operate or install the product.
WARNING
● Turn off electricity at main fuse box (or circuit breaker box) before beginning installation by removing fuse (or
switching off circuit breaker).
● Be careful not to damage or cut the wire insulation (covering) during fixture installation. Do not permit wires to contact
any surface having a sharp edge. To do so may damage or cut the wire insulation, which could cause serious injury
or death from electric shock.
CAUTION
● All electrical connections must be in agreement with local codes, ordinances or the national electric code (NEC).
Contact your municipal building department to learn about your local codes, permits and/or inspections.
● Risk of fire – most dwellings built before 1985 have supply wire rated for 140°F/60ºC. Consult a qualified electrician
before installation.
● Do not connect this fixture to an electrical system that does not provide a means for equipment grounding. Never use
a fixture in a two-wire system that is not grounded. If you are not sure your lighting system has a grounding means,
do not attempt to install this fixture. Contact a qualified, licensed electrician for information with regards to proper
grounding methods as required by the local electrical code in your area.
SAFETY INFORMATION
1
DD
AA
FF
1.Thread the long screws(DD)
through mounting strap(AA),
then secure them with two lock
nuts(FF).
Adjust the length of
the long screws if necessary.
2.Attach the mounting
strap(AA) to the outlet
box using two mounting
screws (CC).
outlet box.Make wire connection
using wire connectors as follow:
source.
Install four Bulbs Type B
Max. 60w(not included)
AA
A
GG
4
Bulb Type B
Max. 60W
(not included)
nuts(GG).
EE
AA
3
the
5
6.Attach the C、D and E to the light
and secure them screw tightly.
Turn on the power at fuse or circuit
box.
A
6
D
E
C

Spare Parts List:
Mounting Hardware
5263MM (1 SET)
Ball Nut
X2
Green Grounding
Screw
X1
AA
CC
FF
EE
BB
Mounting Screw
X2
Wire Connector
X3
Hex Nut
X2
Mounting Strap
X1
Long Screw
X2
DD
GG
Page 3 of 3
TROUBLESHOOTING
CARE AND MAINTENANCE
● To clean, turn off and wipe with a damp, non-abrasive cloth.
1) The light does not come on at all:
a) Make sure the wall switch and circuit breaker are on.
b) Make sure the wiring is correct.
2) Fuse blows or circuit trips when light is turned on.
a) Check for crossed wires, ensure wiring is correct.
If unable to fix any of the above issues, please consult a certified electrician.
Questions, problems, missing parts?
Before returning to your retailer, call our customer service at 1-800-887-6326
Monday – Friday 9:00 a.m. – 5:00 p.m. CST
FIVE-YEAR LIMITED WARRANTY: If, during normal use, this PATRIOT LIGHTING lighting fixture breaks or fails
due to a defect in material workmanship within five (5) years from the date of original purchase, simply bring this
lighting fixture with the original sales receipt back to your nearest MENARDS retail store. At its discretion, PATRIOT
LIGHTING agrees to have the product or any defective part(s) repaired or replaced with the same or similar PATRIOT
LIGHTING product or part free of charge, within the stated warranty period, when returned by the original purchaser
with original sales receipt. This warranty; (1) excludes expendable parts including but not limited to light bulbs; (2) does
not cover damage that has resulted from abuse or misuse; and (3) does not cover any losses, labor, injuries to
persons/property or costs. This warranty does give you specific legal rights and you may have other rights, which vary
from state to state.
R
R
R
R
The following parts are available for re-order if damaged or missing.Call us toll-free at 1-800-887-6326.
HH
II
Crystal Needle
X1
Crystal
X1
Crystal Spare
5112CD (1 SET)