Loading ...
Loading ...
Loading ...
COMMERCIAL DEHUMIDIFIER
B-AIR.COM | 877.800.BAIR | WATER DAMAGE RESTORATION DIVISION
VANTAGE LGR 2200
Trouble ShootingMaintenance
Cleaning the Air Filter
Ensure the dehumidifier is turned OFF and the plug removed from the power
socket before maintenance is carried out.
The working performance of the dehumidifier will be greatly reduced if the filters
become blocked.
1. Remove the filter as shown in the diagram above.
2. Vacuum any derbis from the filter using the vacuum hose and nozzle attachment.
3 Using luke-warm water and mild detergent wash the filter and allow to dry.
4. Once, dry, re-install the filter into the dehumidifier.
Fault Codes
The problems as below are probably real faults. Please check the machine according
to the tips.
filter
pull out from
the left side
WARNING
DO NOT attempt to rectify faults using unqualified personnel.
PROBLEM CAUSE SOLUTION
Unit does not operate
No power to appliance
Connect plug to power socket
and check the power
Switch not turned on Switch on
E4 error is displayed Try to manually drain the water
No water or very little water
Allow unit running more time
Filter is blocked
Insufficient working time
Indoor temperature is too low
Drain hose tied or deflated
Increase the indoor temperature
Clean the filter
Check drain hose
Doors or windows are open or
the bad hermetic house
Seat up the room
Water leakage
The dehumidifying effect
is poor
Residual water has not ruled
out clean or overbank of the unit
Manually drain the water after
power is on
Hot air is exhausted from
the outlet
The normal heat exchange Normal phenomenon
All keys have no effect
With the sound of flowing
water or data voice
Refrigerant flow sound or water
pump working sound
Normal phenomenon
Keys are locked
Press the upper and down key
for 2 seconds at the same time
12 13
C
M
Y
CM
MY
CY
CMY
K
LGR_2200_MANUAL.pdf 7 8/24/16 12:56 PM
Loading ...