30
Freezer Range F5PRO & F10PRO
the door is opened. The switch is located in the top of the door rebate (see Fig. 6 on page 29).
INSTALLING SHELVES
Fit the shelf clips to the ladder racks (see Fig. 2 on page 29) and install the shelves horizontally.
Ensure the clips are located firmly and the shelves are secure before loading the freezer.
FITTING/REMOVING THE ILLUMINATED CANOPY
COMPETENT PERSON ONLY. To fit the canopy, first disconnect the freezer from the power
supply. Remove the right hand door hinge cover. Plug the canopy into the socket that may now
be seen. See Fig. 1 on page 29. Tighten the thumb screws on both sides of the canopy to secure
the canopy to the freezer. Re-connect the freezer to the power supply.
To remove the canopy, first disconnect the freezer from the power supply. Loosen the thumb
screws on both sides of canopy, then pull out the plug for the canopy light – see Fig. 1 on page
29. The canopy may now be removed. Re-fit the right hand door hinge cover. Finally
re-connect the freezer to the power supply.
EASY MAINTENANCE ACCESS
QUALIFIED ENGINEERS ONLY. Husky freezers are designed for easy maintenance. One
feature is that the compressor, condenser and condenser fan are mounted on an easily-
accessible sliding tray. To access this sliding tray, open the door(s) fully and loosen the two
screws (which have now become accessible) on the top on either side of the kick plate – see Fig
5 on page 29. Remove the kick plate by lifting it up and pulling it forward. Loosen the thumb
screws on either side of the sliding tray – see Fig. 4 on page 29. With caution slide out the sliding
tray no more than 300mm.
COMPRESSOR
QUALIFIED ENGINEERS ONLY. To access the compressor, slide out the sliding tray – see ‘Easy
Maintenance Access’.
CLEANING
The condenser MUST be cleaned quarterly. Carefully remove the kick plate (see above for how
to remove the kick plate) and use a soft brush to clean the condenser.
The external and internal surfaces of the unit should be cleaned regularly. Switch the unit off
and disconnect the plug from the mains socket. Remove the drainage hole cover (see Fig. 3 on
page 29). Clean the external and internal surfaces of the unit with a mild soap solution, then
wipe dry. Replace the drainage hole cover. Do NOT use cleansers containing chlorine or other
harsh cleansing agents, as these can damage the stainless steel surfaces and components. Use
mild soapy water to clean the gasket and seals.
GETTING SERVICE ASSISTANCE
The cooling system is a hermetically sealed circuit and does not require any maintenance other
than regular cleaning (see ‘Cleaning’).
If the unit fails to work, first check the power supply. If you cannot locate the reason for the
failure, please contact your supplier, stating the model and serial number of the cabinet. You
may find this information on the rating plate, which is affixed inside the unit on the top right-hand
interior wall.
International PRO upright manual 240317 EDITION 2 v2.indd 30 28/03/2017 08:34