Craftmade END52WW5P Enduro Plastic 52" White Outdoor Ceiling Fan

User Manual - Page 7

For END52WW5P.

PDF File Manual, 18 pages, Read Online | Download pdf file

END52WW5P photo
Loading ...
Loading ...
Loading ...
page 6
7. Canopy Assembly.
Locate 2 screws on underside of hanging bracket and
remove screw closest to the open end of the hanging
bracket. Partially loosen the other screw. Lift canopy
to hanging bracket. Place rounded part of slotted
hole in canopy over loosened screw in hanging
bracket and push up. Twist canopy to lock. Re-insert
screw that was removed, and then tighten both
screws securely.
canopy
hanging bracket
screw
screw
6. Wiring.
black
black
white
white
blue
black supply wire
ground
(green
or bare)
white supply wire
*
from ceiling
from fan
ground
(green or bare)
WARNING: Turn off circuit breakers to current fixture
from breaker panel and be sure switch is turned to the
OFF position.
CAUTION: Be sure outlet box is properly grounded and that
a ground wire (GREEN or Bare) is present.
Make sure all electrical connections comply with Local
Codes or Ordinances and the National Electrical Code. If
you are unfamiliar with electrical wiring or if the
house/building wires are different colors than those
referred to in the instructions below, please use a qualified
electrician.
Note: Excess lead wire length from the fan can be cut to
the desired length and then stripped.
WARNING: If using this fan in a WET location, this fan
must be connected to a supply circuit that is protected
by a Ground Fault Circuit Interrupter (GFCI) to reduce the
risk of personal injury, electrical shock or death.
When downrod is secured in place on the hanging
bracket, electrical wiring can be made as follows:
Connect BLACK wire from fan to BLACK wire from
ceiling with wire connector provided.
Connect WHITE wire from fan to WHITE wire from
ceiling with wire connector provided.
Connect all GROUND (GREEN) wires together from fan
to BARE/GREEN wire from ceiling with wire connector
provided.
Since this fan does not come with a light kit, you will
need to cap off the BLUE wire with a wire connector (as
shown with arrow in diagram).
[Note: If you elect to purchase a light kit for the fan, the
BLUE wire from the fan must be connected to the
BLACK wire from the ceiling instead.]
* Wrap each wire connector separately with electrical
tape as an extra safety measure.
This fan is remote control adaptable (remote
control sold separately). Note: Only remote controls
approved for WET location can be used with this fan.
Loading ...
Loading ...
Loading ...