Installation Instructions
1. Turn off the circuit breaker (s) (30 amp) or remove the dryer's
circuit fuse at the electrical box.
2. Be sure the dryer cord is unplugged from tile wall receptacle.
3. Remove the power cord cover located at the lower back.
4. Remove and discard ground strap. Keep the green
ground screw for step 7.
5. Install 3/4 in. UL recognized strain relief to power
cord entry hole. Bring power cord through strain relief.
6. Connect power cord as follows:
A. Connect the 2 hot lines to the outer screws of
the terminal block (marked L1 and L2).
B. Connect the neutral (white) line to tile center of
the terminal block (marked N).
7. Attach ground wire of power cord with the green ground
screw (hole above strain relief bracket). Tighten all
terminal block screws (3) completely.
8. Properly secure power cord to strain relief.
9. Reinstall the coven
,_WARNING: NEVER LEAVE THE
COVER OFF OF THE TERMINAL BLOCK.
CONNECTING DRYER USING 3-WIRE
CONNECTION
IFREQUIRED,BYLOCALCODE,
INSTALLEXTERNALGROUND
(NOTPROVIDED)TOGROUNDED
METAL,COLDWATERPIPE,OR GREEN GROUND
OTHERESTABLISHEDGROUNDGROUND _TRAP
DETERMINEDBYAQUALIFIEDSCREW
ELECTRICIAN. HOT
WIRE
STRAINRELIEF
BRACKET
3/4",UL
RECOGNIZED
RELIEF
NEUTRAL
HOT
(White) WIRE
/
3#10AWGMINIMUMCOPPER
COVER CONDUCTORSOR120/240V30APOWER
SUPPLYCORDKITMARKEDFORUSE
WITHDRYERS&PROVIDEDWITHCLOSED
LOOPORSPADETERMINALSWITH
UPTURNEDENDS(NOTSUPPLIED).
1. Tm'n off the circuit breaker (s) (30 amp) or remove the dryer's
circuit fuse at the electrical box.
2. Be sure the dryer cord is unplugged from the wall.
3. Remove tile power cord cover located at the lower back.
4. Install 3/4 in. UL recognized strain relief to power cord
entry hole. Bring power cord through strain relief.
5. Connect power cord as Mlows:
A. Connect the 2 hot lines to the outer screws of the
terminal block (marked L1 and L2).
B. Connect the neutral (white) line to the center of
the terminal block (marked N).
6. Be sure ground strap is connected to neutral (center)
terminal of block and to green ground screw on cabinet
rear. Tighten all terminal block screws (3) completely.
7. Properly secure power cord to strain relief.
8. Reinstall tile cover.
,_WARNING: NEVER LEAVE THE
COVER OFF OF THE TERMINAL BLOCK.
3
[] EXHAUST INFORMATION
A
JIIWARNING - USE ONLY METAL 4-IN. DUCT.
DO NOT USE DUCT LONGER THAN SPECIFIED
IN THE EXHAUST LENGTH TABLE.
Using exhaust longer than specified length will:
Increase the drying times and the energy cost.
Reduce the dryer life.
Accumulate lint, creating a potential fire hazard.
The correct exhaust installation is YOUR RESPONSIBILITY.
Problems due to incorrect installation are not covered
by the warranty.
The MAXIMUM ALLOWABLE length of the exhaust system
depends upon the type of duct, nmnber of turns, the type of
exhaust hood (wall cap), and all conditions noted below. Both
rigid and flexible metal duct are shown in the table below.
EXHAUST LENGTH
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Use only for short
run installations
4"DIA.
Recommended
No. of 90_ Rigid Flexible Rigid Flexible
Elbows Metal Metal Metal Metal
0 90 Feet 55 Feet 60 Feet 45 Feet
1 60 Feet 40 Feet 45 Feet 30 Feet
2 45 Feet 30 Feet 35 Feet 20 Feet
3 35 Feet 20 Feet 25 Feet 15 Feet
4 25 Feet 15 Feet 15 Feet 10 Feet
If using flexible metal duct, please refer to page 5.
EXHAUST SYSTEM CHECK LIST
HOOD OR WALL CAP
Terminate in a manner to prevent back draf& or entry of birds or
other wildlifK
Termination should present minimal resistance to the exhaust air flow
and should require little or no maintenance to prevent clogging.
Never install a screen in or over tfie exhaust duct. This could cause lint build up.
Wall caps must be installed at least 12 in. above g_ound level or any other
obstruction with the opening pointed down.
If roof vents or louvered plenums are used, they must be equivalent to a
4-in. dampened wall cap in regard to resistance to air flow, prevention of
back drafts, and maintenance required to prevent cloggting.
SEPARATION OF TURNS
For best performance, separate all turns by at least 4 ft. of straight duct,
including distance between last turn and exhaust hood.
TURNS OTHER THAN 90°
One turn of 450 or less may be ignored.
Two 450 turns should be treated as one 90 ° turn.
Each turn over 45 o should be treated as one 900 turn.
SEALING OFJOINTS
All joints should be tight to avoid leaks. The male end of each section of
duct must point away from the dryer.
Do not assemble the ductwork with fasteners that extend into the duct.
They will serve as a collection point fbr lint.
Duct joints can be made air and moisture-tight by wrapping the
overlapped joints with duct tape.
Horizontal runs should slope down toward tile outdoors 1/2 inch per foot
INSULATION
Duct work that runs through an unheated area or is near air conditioning
should be insulated to reduce condensation and lint build-up.