Storing the portable air conditioner
In order to dry it and to prevent the formation of moulds, leave the
portable air conditioner running in awarm room in the fan mode for
approximately 12 hours.
Disconnect the flexible hose B1 and store it in asafe place out of the
reach of children.
Drain all the condensate from the condensate tank – see chapter
Condensate drain outlet”.
Clean the air filters and reinstall them. Wipe the outer case of the
portable air conditioner. Remove the batteries from the remote control.
Store the air conditioner in acool, dry and dark location.
Condensate drain outlet
If the water level inside the condensate tank reaches apredetermined
level, the portable air conditioner will show “Ft” (full condensate
tank) on the display C6. In order to drain the condensate from the air
conditioner, proceed as follows:
1. Disconnect the power plug from the power socket.
2. Carefully re-locate the portable air conditioner to alocation where
the water may be drained.
3. Underneath the drain outlet A11, place acontainer into which the
condensate will flow. Carefully remove the plug of the drain outlet
A11. Connect the drain hose B6 and allow the condensate to flow
out.
4. Once the condensate tank is empty (condensate has stopped
flowing), disconnect the drain hose B6 and put the plug back into the
drain outlet A11.
5. Insert the power plug into apower socket and turn on the portable air
conditioner.
If you need to ensure the condensate to be continuously drained from
the portable air conditioner, it is possible to connect the drain hose B6
to awaste water drain. Proceed as follows:
1. Disconnect the power plug from the power socket.
2. Remove the plug of the top drain outlet A8. Connect the drain
hose B6. If the length of the drain hose B6 is insufficient, then it is
necessary to purchase alonger hose of the same type. Never extend
the length of the drain hose B6 using extensions.
3. Connect the end of the drain hose B6 to the waste water drain.
4. Insert the power plug into apower socket and turn on the portable air
conditioner.
Note:
The drain hose B6 should be installed at the same height or
lower than the top drain outlet A8. Otherwise, the condensate
will not be properly drained from the condensate tank.
Putting into operation again
Check that the power cord and plug are not damaged and that the
air filters are clean. Insert anew set of batteries into the remote
control. Proceed according to the instructions in section “Inserting and
replacing batteries”. Install the portable air conditioner according to
the instructions contained in the preceding part of this user’smanual
“Installation”.
TROUBLESHOOTING
Error messages
Shown on
the display
Meaning Solution
Low
temperature
The portable air conditioner has
asystem that prevents freezing at very
low temperatures.
The air conditioner will start again once
the internal system is defrosted.
Defect of the
heat sensor
Contact an authorised service centre.
Full
condensate
tank
Empty the condensate tank. Proceed
according to the instructions in section
"Condensate drain outlet" described
previously in this user'smanual.
Note:
In the event that one of the aforementioned faults occurs,
turn off the portable air conditioner and check for the cause of
the fault. Turn it on again, and if the fault reoccurs, turn it off,
disconnect the power cord from the power socket and contact
the manufacturer, an authorised service centre or aperson with
relevant qualifications and have the unit repaired.
Troubleshooting
Before contacting an authorised service centre, please check the
appliance according to the following instructions:
Problem Possible cause Remedy
The portable air
conditioner did
not turn on.
There is no current in
the power socket.
Engage the
circuit breaker or,
alternatively, try
adifferent power
socket.
The power plug is not
inserted in apower
socket.
Connect the power
plug to the power
socket.
The internal safety fuse
is disengaged.
Wait 30 minutes, and
if the problem persists,
please contact an
authorised service
centre.
The portable air
conditioner runs
only for ashort
time.
The flexible air
exhaust hose B1 is
not connected or it is
blocked.
Turn off the air
conditioner, disconnect
the hose, check that
it is not blocked and
reconnect the hose.
Air inlets A7 and A9 are
blocked.
Remove the obstacles
preventing air supply to
the inlets.
The portable air
conditioner is on,
but is not cooling.
The windows and doors
of the room are open.
Make sure that all
doors and windows are
closed.
There are heat sources
inside the room.
If possible remove
these heat sources.
The flexible air
exhaust hose B1 is not
connected.
Attach the flexible
hose B1.
The room area is too
large.
Perform adouble-
check of the cooled
area.
An unpleasant
odour is sensed
while it is running.
The air filters are
clogged with dirt and
dust or animal fur.
Turn off the air
conditioner and clean
the filters according
to the provided
instructions.
The portable
air conditioner
turns off approx.
3minutes after
it is turned on
again.
Then
compressor'ssafety
fuse is protecting the
air conditioner against
damage if turned on
sooner than after 3
minutes.
Wait several minutes
and then turn the air
conditioner on again.
An error message
appeared on the
display C1.
Proceed according
to the instructions
in section "Error
messages".
Loading ...
Loading ...