Loading ...
Loading ...
Loading ...
10
Place Grates and Burner Caps
To make sure cap is properly aligned and leveled, move burner cap around on
burner base. Pegs in the burner base fit into recess in underside of burner cap.
Burner cap must be correctly seated on burner base for proper operation of
burner.
Testing for Gas Leaks
WARNING
!
To avoid property damage or
serious personal injury, never use
a lighted match to test for gas
leaks.
After final gas connection is made,
test all connections in gas supply
piping and cooktop for gas leaks.
1. Place soap suds on connection.
Bubbles appear if leak is
present.
Testing for Gas Leaks
2. Tighten joint if leak is at factory
fitting.
If leak is not at factory fitting,
unscrew, apply more joint
compound, and tighten to
correct leak.
3. Retest connection for leak after
tightening.
Retest any connections that
were disturbed.
A
B
C
Correct
Not centered
Too small
Too large
A—Burner grate
B—Burner cap
C—Burner base
Make sure proper cap size is on each burner base. Burner does not burn
properly if wrong size burner cap is placed on burner base.
Turn on burners to check for proper operation. See
Operating Surface Burners
section for burner operating instructions.
Installation
Loading ...
Loading ...
Loading ...