Whirlpool ED5FHEXNS00 25.3 Cu. Ft. Side by Side Refrigerator

Use & Care Guide - Page 4

For ED5FHEXNS00.

PDF File Manual, 36 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
E(ectrica_ Shock Hazard
Pmuginto a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter,
Do not use an extension cord°
FaiJure to follow these }nstructiens can resumt }n death,
fire, or emectricamshock.
Before you move your refrigerator into its final location, it is
important to make sure you have the proper electrical connection:
Recommended grounding method
A 115 Volt, 60 Hz., AC only 15 or 20 ampere fused, grounded
electrical supply is required. It is recommended that a separate
circuit serving only your refrigerator be provided. Use an outlet
that cannot be turned off by a switch. Do not use an
extension cord.
NOTE: Before performing any type of installation, cleaning, or
removing a light bulb, turn the control (Thermostat, Refrigerator or
Freezer Control depending on the model) to OFF and then
disconnect the refrigerator from the electrical source. When you
are finished, reconnect the refrigerator to the electrical source and
reset the control (Thermostat, Refrigerator or Freezer Control
depending on the model) to the desired setting.
Read all directions carefully before you begin.
IMPORTANT:
If you turn the refrigerator on before the water line is
connected, turn the ice maker OFF.
All installations must meet local plumbing code requirements.
Use copper tubing and check for leaks. Install copper tubing
only in areas where the household temperatures will remain
above freezing.
Tools Required: Flat-blade screwdriver, 7/_6in. and 1/2in. open-
end wrenches or two adjustable wrenches, 1/4in. nut driver and
drill bit, hand drill or electric drill (properly grounded).
NOTE: Your refrigerator dealer has a kit available with a 1/4in.
(6.35 ram) saddle-type shutoff valve, a union, and copper tubing.
Before purchasing, make sure a saddle-type valve complies with
your local plumbing codes. Do not use a piercing-type or 3/16in.
(4.76 mm) saddle valve which reduces water flow and clogs more
easily.
Water Pressure
A cold water supply with water pressure of between 30 and
120 psi (207-827 kPa) is required to operate the water dispenser
and ice maker. Ifyou have questions about your water pressure,
see "Troubleshooting" or call a licensed, qualified plumber.
Reverse Osmosis Water Supply
If a reverse osmosis water filtration system is connected to your
cold water supply, the water pressure to the system needs to be a
minimum of 40 to 60 psi (276 - 414 kPa),
Ifthe water pressure to the reverse osmosis system is less than 40
to 60 psi (276 - 414 kPa) a booster pump can be inserted into the
small tubing that goes from the cold water line to the reverse
osmosis system.
If the water dispenser is still not dispensing water properly:
Check to see whether the sediment filter in the reverse
osmosis system is blocked. Replace the filter if necessary.
Allow the storage tank on the reverse osmosis system to refill
after heavy usage,
If your refrigerator has a water filter cartridge, it may further
reduce the water pressure when used in conjunction with a
reverse osmosis system. Remove the water filter cartridge.
If you have questions about your water pressure, refer to
"Troubleshooting" or call a licensed, qualified plumber.
Read all directions before you begin.
IMPORTANT: Ifyou turn the refrigerator on before the water line is
connected, turn the ice maker OFR
Connecting to Water Line
1. Unplug refrigerator or disconnect power.
2. Turn OFF main water supply. Turn ON nearest faucet long
enough to clear line of water.
3. Locate a 1/2in. to 11/4in. (1.25 cm to 3.18 cm) vertical COLD
water pipe near the refrigerator.
NOTE: Horizontal pipe will work, but drill on the top side of the
pipe, not the bottom. This will help keep water away from the
drill and normal sediment from collecting in the valve.
4. Determine the length of copper tubing you need. Measure
from the connection on the lower left rear of refrigerator to the
water pipe. Add 7 ft. (2.1 m) to allow for cleaning. Use 1/4in.
(6.35 mm) O.D. (outside diameter) copper tubing. Be sure both
ends of copper tubing are cut square.
5. Using a grounded drill, drill a 1/4in. hole in the cold water pipe
you have selected.
............ /
7 ....................2
.............. 3
1.Cold waterpipe 5. Compression sleeve
2. Pipe clamp 6. Shutoff valve
3. Copper tubing 7.Packing nut
4. Compression nut
6. Fasten the shutoff valve to the cold water pipe with the pipe
clamp. Be sure the outlet end is solidly in the 1/4in. drilled hole
in the water pipe and that the washer is under the pipe clamp.
Tighten the packing nut. Tighten the pipe clamp screws
carefully and evenly so washer makes a watertight seal. Do
not overtighten or you may crush the copper tubing.
7. Slip the compression sleeve and compression nut on the
copper tubing as shown. Insert the end of the tubing into the
outlet end squarely as far as it will go. Screw compression nut
onto outlet end with adjustable wrench. Do not overtighten.
8. Place the free end of the tubing in a container or sink, and turn
ON the main water supply. Flush the tubing until water is clear.
Turn OFF the shutoff valve on the water pipe. Coil the copper
tubing.
Loading ...
Loading ...
Loading ...