"L2"Diagnostic Code (low or no line voltage condition):
The drum will turn, but there may be a problem with your home power supply keeping
the dryer's heater from turning on. The dryer will continue to run when this diagnostic
code is present. Press any key to clear the code from the display and return to the
estimated time remaining.
Try the following:
Check to see if a household fuse has blown or circuit breaker has tripped. Electric dryers
use two household fuses or breakers. Replace the fuse or reset the circuit breaker.
In the U.S.A. - Confirm the power cord is properly installed. Refer to "Electrical
Connection" for details.
Select a Timed Cycle, and restart the dryer.
If the message persists, consult a qualified electrician.
"AF" (low airflow condition):
The dryer will continue to run when this diagnostic code is present. Press any key to clear
the code from the display and return to the estimated time remaining.
Try the following:
Clean lint screen.
Check to see if the vent run from the dryer to the wall is crushed or kinked.
Confirm the vent run from the dryer to the wall is free of lint and debris.
Confirm the exterior vent exhaust hood is free of lint and debris.
Confirm your vent system falls withing the recommended run length and number of
elbows for the type of vent you are using. Refer to "Plan Vent System" for details.
Select a Timed Cycle, and restart the dryer.
If the message persists, have your entire home venting run cleaned.
Clothes are not drying satisfactorily, drying times are too long, or load is too hot
Is the lint screen clogged with lint?
I.int screen should be cleaned before each load.
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death
or fire.
Is the exhaust vent or outside exhaust hood clogged with lint, restricting air movement?
Run the dryer for 5-1 0 minutes. Hold your hand under the outside exhaust hood to check
air movement. If you do not feel air movement, clean exhaust system of lint or replace
exhaust vent with heavy metal or flexible metal vent. See the Installation Instructions.
Are fabric softener sheets blocking the grille?
Use only one fabric softener sheet, and use it only once.
Is the exhaust vent the correct length?
Check that the exhaust vent is not too long or has too many turns. I.ong venting will
increase drying times. See the Installation Instructions.
Loading ...