Cooling Mode
Adjust fan speed and air temperature to suit your desired comfort level.
Temperature setting range is 16°C- 32°C (61°F- 89°F).
Fan Mode (FAN)
For air circulation without air conditioner cooling.
Dehumidifying Mode (DRY)
Air is dehumidified as it passes through the unit, without being in full cooling mode. If room tempera-
ture is higher than 25°C (77°F) fan speed can be adjusted; otherwise fan speed is preset to LOW.
Note: If the unit will be used mainly as a dehumidifier, do not connect the exhaust hose. Continuous
drainage is then necessary (refer to Continuous Draining for Dehumidifier Mode).
USE & OPERATION (CONTINUED)
MODE CONTROL
3 settings: Cool, Dehumidify, Fan.
The corresponding indicator light will illuminate to indicate the current mode setting.
FUNCTION BUTTONS (CONTINUED)
EN 5
Settings: COOL, DRY and FAN.
Temperature setting range is 16°C - 32°C (60°F - 90°F).
Air Conditioning Mode (COOL)
Fan speed is preset to LOW.
Sleep Mode (SLEEP)
When the Sleep Mode is activated in Air Conditioning mode, the set temperature will increase by 1°F
or 1°C after the first hour of cooling and will increase a further 1°F or 1°C after the second hour of
cooling. The unit will maintain this temperature for 5 hours. The set temperature will then reduce by
1°F or 1°C on the seventh hour and reduce a further 1°F or 1°C on the tenth hour. Sleep mode will
then deactivate automatically.
Note: The Sleep Mode can be deactivated during cooling mode by pressing any button at any time.
*Applicable for models with Heating feature only.
Heating Mode* (HEAT)
When heating mode is selected the indicator light will shine. Heating is activated only when the ambient
temperature is below 25°C (77°F). In this mode, the desired temperature can be set between 16°C- 25°C
(61°F- 77°F).
Note: The air exchange hoses must vent outside the room when using heating mode.
4 settings: Cool, Heater*, Dehumidify & Fan.
Settings: COOL, DRY, FAN and HEAT*.
In this mode, the desired temperature can be set between 16°C - 32°C (60°F - 90°F). When in heating
mode condensation must be drained from the lower drain plug.
In Heating Mode*, the set temperature will reduce by 2°F or 2°C after the first hour of heating* and will
reduce a further 2°F or 2°C after the second hour of heating*. The unit maintains heating* at this
temperature for 5 hours. Then, the set temperature will increase 2°F or 2°C at the seventh hour and
will increase a further 2°F or 2°C on the tenth hour. Sleep mode will then deactivate automatically.
Note: The Sleep Mode can be deactivated during cooling or heating* mode by pressing any button at
any time.