Auxiliary controls on your Zoneline.
I MODE 3 I
[ MODE 4
[ MODE 5
[ MODE 6
Freeze Sentinel/Heat Sentinel
In the default setting for Mode 3, HeatSentinelis off, Freeze
Sentinel is on,
PressMODEuntil a 3 appears in the first digit of the display for
Freeze Sentinel mode,/he COOLLEDlight on the main control
will be on, PressMODEagain to change to the HeatSentineZ The
HEATLEDlight on the main control will be on, Pressthe down
arrow for OFF"LJ "or the up arrow for ON "r'l," This is shown
in the second digit of the display, PressAUXSETto confirm your
selection and exit AUX SETmode, or press MODEto continue
setting other functions,
When Freeze Sentinel is activated, it automatically provides
heat without user interface, This helps to prevent plumbing
damage by turning the heater and indoor fan ON at 41°F and
OFFat 46%,
When Heat Sentinel is activated, it automatically provides
cooling without user interface, This helps to prevent an
excessively hot room by turning the air conditioner ON at 85°F
and OFF at 80°F,
NOTE:These functions are active whenever the unit is
plugged in, even if the unit is in the STOPposition,
-- HIGH _ COOL
-- LOW -- FAN
--AUTO --HEAT
FreezeSentinelOFF
-- HIGH "" COOL
-- LOW -- FAN
--AUTO --HEAT
FreezeSentinelON
--HIGH --COOL
-- LOW -- FAN
-- AUTO "" HEAT
Heat SentinelOFF
--HIGH --COOL
-- LOW -- FAN
-- AUTO "" HEAT
HeatSentinel ON
Constant ON Fan
The default setting for Mode 4 is OFF,
PressMODEuntil a 4 appears in the first digit of the display to set
the fan to run continuously at high speed,even ifthe unit is in
the STOPposition, Pressthe down arrow for OFF"u" or the up
arrow for ON "r'-I," Thisis shown in the second digit of the
display, PressAUXSETto confirm your selection and exit AUX
SETmode, or press MODEto continue setting other functions,
Constant Constant
FanOFF FanON
Temperature Limiting
The default settinq for Mode 5 is as follows:
Cool: 2 (66% to 85"°F)
Heat: 5 (60% to 78%)
PressMODEuntil a 5 appears in the first digit of the display for
Temperature Limiting cool mode, The COOLLEDlight on the
main control will be lit, To change to heat mode, press MODE
again and the HEATLEDlight on the main contro/will be lit, To
set the temperature limits, press the up or down arrow keys,The
second digit of the displa#_willbe between 0 and 7 depending on
the limit you want to set,/he char shows the limits available,
PressAL1XSETtoconfirm your selection and exit AUX SETmode,
or press MODEto continue setting other functions,
Temperaturelimits--Cool Temperaturelimits--Heat
0 = 60°Fto 85°F 0 = 60°Fto 65°F
1 = 64°Fto 85°F 1 = 60°Fto 70°F
2 = 66°Fto 85°F 2 = 60°Fto 72°F
3 = 68°Fto 85°F 3 = 60°Fto 74°F
4 = 70°Fto 85°F 4 = 60°Fto 76°F
5 = 72°Fto 85°F 5 = 60°Fto 78°F
6 = 74°Fto 85°F 6 = 60°Fto 80°F
7 = 76°Fto 85°F 7 = 60°Fto 85°F
_2 -- HIGH _COOL
-- LOW -- FAN
--AUTO --HEAT
TemperatureLimitingCool- Limit 2
HIGH --COOL
99 -,0w
: --AUTO _HEAT
TemperatureLimitingHeat- Limit 3
Remote Thermostat- Class 2
The default setting for Mode 6 is OFF,
Setting this mode to ON will allow the unit to operate with a Class
2 Remote Control Wall Thermostat, PressMODEuntil a 6 appears
in the first digit of the display for Class 2 mode, Pressthe down
arrow to turn the option OFF" LJ," Pressthe up arrow to turn this
option ON "r-I," Thisis shown inthe second digit of the display,
PressAUXSETto confirm your selection and exit AUZ SETmode,
or press MODEto continue setting other functions,
Class2 OFF Class2 ON