ProTemp PT-40-GFA Propane Heater

User Manual - Page 8

For PT-40-GFA.

PDF File Manual, 36 pages, Download pdf file

Loading ...
Loading ...
Loading ...
© 2017, Pinnacle Climate Technologies, Inc. Propane Forced Air Heater User’s Manual
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
WHILE CONNECTED TO A POWER SOURCE
®
Storage / Maintenance
Always disconnect the heater from the LP cylinder before
putting the heater into storage. If for any reason the heater
is to be stored indoors, the tank MUST be disconnected
from the LP cylinder, and the cylinder stored outdoors in
a well-ventilated area, out of the reach of children, and in
accordance with the Standard for Storage and Handling
of Petroleum Gases, ANSI/NFPA 58 - latest edition and
Natural Gas and Propane Installation Code, CSA B149.1.
The plastic valve plug or valve cover supplied with the
cylinder must be re-installed on the valve to protect the
fitting from damage.
NOTE: Installation and repair of this heater should be
done by a qualified service person.
ALWAYS be sure to follow proper maintenance
procedures. This should include cleaning the inside of the
heater once a month and checking the spark gap at least
once a heating season. Re-gap the terminals to 0.160”
(4mm)
7
Never store
an LP cylinder
inside of a
building or near any other gas or oil
burning appliances.
DANGER
Wiring Diagrams
PT-40-GFA
PT-60V-GFA / PT-125V-GFA-A / PT-150V-GFA-A
Figure 6
Figure 7
Figure 6
Loading ...
Loading ...
Loading ...