Troubleshooting77ps...
Troubleshooting -tips:Save time and money!
Possible Causes What ToDo
Airconditioner
doesnotstart
The air conditioner
is unplugged.
"Make sure the air conditioner i)lug is pushed
comi)letely into the outlet,
The fuse is blown/circttit " Check the house disc/circuit breaker box and rel)lace
breaker is tripped, the fi/se or reset the breakeI;
Power failure. If power thilure occurs, turn tile air conditioner OFF.
_'hen power is restored, wait 3 mim/tes to restart the
air conditioner to prevent tripl)ing of tile compressor
()verl();i d.
Air conditioner does Airflow is restricted. Make sure there are no curtains, blinds or flu'niture
not cool as # should blocking tile fi'ont of tile air condifioneL
The temp control may On models with touch pads: ]n COOL mode, press the
not be set correctly, DECREASE pad.
" On models with control knobs, tt/rl] the temperature
knob to a higher munbeL
The air filter is dirty. " Clean tile filter at least every 30 dins.
See tile Operating Instructionssecfi,;n.
The room may have been hot. _&]wn tile air conditioner is tix_t turned on you need
to allow tilne fi)l" tile rool// to COO1 dowl].
Cold air is escaping. Check fin" open flU'hate registe_ and cold air returns.
Set the air conditioner's vent to the closed position.
Cooling coils have iced up. See "Air conditioner freezing up" below,
Air conditioner lee blocks the air flow On models with control knobs, set tile mode control
freezing up mad stops the air conditioner at HIGHFANor HIGHCOOLwith tile temp at I or 2.
from cooling the room. On models \dth touch pads, set tile controls at
HIGH FAN or HIGH COOL and set the tlwm_ostat to
a higher temperatm'e.
The remote control is The batteries are h_serted Check tile l)osition of tile batteries. Tile)' should be
not working incorrectly, inserted in the opposite (+) and (-) direction.
The batteries may be dead. "Rel)lace tile batteries.
Water drips outside Hot, hmnid weather. This is n(mnal.
Water drips indoors The air conditioner is not For proper water disposal, make sure tile air conditioner
tilted to the outside, slants slightly fl'om tile case fl'oi]t t(> tile rein:
Water collects in Moisture removed from air "This is nom, al for a short period in areas with little
basepan and drains into base pan, humidly'; nomml for a hmger period in ve_' humid areas.
Function error code. Lrnl_lug tile air condifione_: _'ait 3 minutes and plug it
in the display back in.
TIMERfeature not A power outage or interruption "/n tile case of a l_ower outage or interrul)tion, tile trait
workingproperly occurred. TIMER tbatm'e will reset to tile original setting, xA)u may
need to set a new time if desired.
14
Normal Operating Sounds
::Ji::Y)u may hear a pinging noise caused by water
being picked up and thrown against the
condenser on rainy da)s or when the humidit},
is high. This design teature helps relnove
moisttu'e and imi)rove efficiency.
_: Y_m inav hear the thermostat click when the
coml)ressor cycles on and off.
::Ji::Water will collect in the base pan durii_g
high lmmiditv or on rainy da)s. The water
nlay oveI_lOW and drip ti'oln the outdoor side
of the trait.
!i_:The tim max rim exen when the comi.wessor
does not.