Dryer Dimensions
36 _l
(61.4 cm)
501/2''
(128.27 cm)
*28,65"
(72.77 cm), 27"
(68.6 cm)
*Most installations require a minimum 5" (12.7 cm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting
Requirements."
Installation spacing for recessed area or closet installation
The following spacing dimensions are recommended for this
dryer. This dryer has been tested for spacing of 0" (0 cm)
clearance on the sides and rear. Recommended spacing should
be considered for the following reasons:
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door and
floor moldings.
Additional spacing should be considered on all sides of the
dryer to reduce noise transfer.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
Companion appliance spacing should also be considered.
Custom undercounter installation - Dryer only
'I"'"
36"rnin
1"* _ _""-27"---_ _ 1"*
2 5 cm 686 cm 2.5 cm
*Required spacing
Closet installation - Dryer only
1
24 in?* _ ,
(155 crn2) '
t1 '°'°*
I1"*1_-28.65"÷1s"**l
(2.5crn) (72.77 crn)(12.7crn)
A B
A. Side view - closet or confined area
B. Closet door with vents
3"*
(7.6crn)
3"*
"--/F(7.6crn)
Recessed or closet installation - Dryer on pedestal
I olo
1"-_11_- 27,,--_11_- 1,,
(2.5cm)
1"*11<-28.65"--_ls"**l
{68.6cm) {2.5 cm) {2.5crn) {72.77cm) (12.7crn)
A B
A. Recessed area
B.Side view - closet or confined area
*Required spacing
**For side or bottom venting, 0" (0 cm) spacing is allowed.
Recommended installation spacing for cabinet
installation
For cabinet installation, with a door, minimum ventilation
openings in the top of the cabinet are required.
" . m) 7"*(17.8 cm)
5"** 28.65"1_,,,
(12.7 crn) (72.77 crn) (2.5 crn) (2.5 cm)(68.6 crn) (2.5 crn)
II
9"*
(22.9 crn)
1" 27" 1"
*Required spacing
**For side or bottom venting, 0" (0 cm) spacing is allowed.
*Required spacing
**For side or bottom venting, 0" (0 cm) spacing is allowed.