Mr. Heater MHVFIH10LPT

User Manual - Page 9

For MHVFIH10LPT.

PDF File Manual, 16 pages, Download pdf file

Loading ...
Loading ...
Loading ...
9
Installation Instructions and Owner’s Manual
Unvented Liquid Propane Fired Room Heater
Figure 11
Low Pressure
Test Pressure Equal To or Less Than ½ psig (3.5 kPa)
1. Close equipment shutoff valve (see gure 12).
2. Pressurize supply piping system by either using
compressed air or opening propane/LP supply
valve.
3. Check all joints from the propane/LP supply
valve to equipment shutoff valve (see gure
13). Apply mixture of liquid soap and water to
gas joints. Bubbles forming show a leak.
4. Correct all leaks at once.
5. Depressurize and relieve pressure from supply
piping system.
Pressure Testing Heater Gas Connections:
1. Make sure that the heater supply piping sys-
tem is connected and has been leak tested as
described above.
2. Make sure control knob of heater is in OFF
position.
3. Open equipment shutoff valve (see gure 12).
4. Open propane/LP supply valve.
5. Check all joints from equipment shutoff valve
to control valve (see gure 13). Apply mixture
of liquid soap and water to gas joints. Bubbles
forming show a leak.
6. Correct all leaks at once.
7. Light heater (see Operating Your Heater, page 10.
8. Turn off heater (see To Turn OFF Gas to
Appliance, page 10.
9. Replace lower front panel.
OPERATING YOUR HEATER
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions
exactly, a re or explosion may result causing
property damage, personal injury or loss of life.
A. This appliance has a pilot that must be lighted
by hand. When lighting the pilot, follow these
instructions exactly.
B. BEFORE LIGHTING smell all around the
appliance area for gas. Be sure to smell next to
the oor because some gas is heavier than air
and will settle on the oor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call you gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
Figure 12
If you can not reach your gas supplier, call the
re department.
Use only your hand to push in or turn the gas
control knob. Never use tools. If knob will not
push in or turn by hand, don’t try to repair it; call
a quali ed service technician or gas supplier.
Force or attempted repair may result in a re or
explosion.
Figure 13
Equipment
Shutoff Valve
Open
Closed
Pressure
Regulator
Heater
Cabinet
Ground Joint Union
Equipment
Shutoff Valve
From LP tank
(11” W.C. to 14”
W.C. Pressure)
Tee Joint
1/8” NPT Plug Tap
Cap
Pipe Nipple
Tee Joint
3/8” NPT Pipe Nipple
Sediment
Trap
Test Gauge
Connection
Reducer Bushing
to 1/8” NPT
3” Minimum
Loading ...
Loading ...
Loading ...