Loading ...
Loading ...
Loading ...
Installation
40
Burner and nozzle characteristics tables
1 Natural gas G20 - 20 mbar AUX SR UR2
Rated heating capacity (kW) 1.0 1.8 4.2
Nozzle diameter (1/100 mm) 72 97 145
Pre-chamber (printed on nozzle) (X) (Z) (F3)
Reduced flow rate (W) 400 500 1400
2 Natural gas G20 - 25 mbar AUX SR UR2
Rated heating capacity (kW) 1.10 1.8 4.2
Nozzle diameter (1/100 mm) 72 94 145
Pre-chamber (printed on nozzle) (X) (Z) (H3)
Reduced flow rate (W) 400 500 1400
3 Natural gas G25.1 - 25 mbar AUX SR UR2
Rated heating capacity (kW) 1.10 1.8 4.2
Nozzle diameter (1/100 mm) 77 100 152
Pre-chamber (printed on nozzle) (F1) (Y) (F3)
Reduced flow rate (W) 400 500 1400
4 Natural gas G25 - 20 mbar AUX SR UR2
Rated heating capacity (kW) 1.0 1.8 4.2
Nozzle diameter (1/100 mm) 77 100 165
Pre-chamber (printed on nozzle) (F1) (Y) (H3)
Reduced flow rate (W) 400 500 1400
5 Natural gas G2.350 - 13 mbar AUX SR UR2
Rated heating capacity (kW) 1.0 1.8 4.0
Nozzle diameter (1/100 mm) 94 120 190
Pre-chamber (printed on nozzle) (Y) (Y) (F3)
Reduced flow rate (W) 400 500 1400
Loading ...
Loading ...
Loading ...