Installation Instructions
_] CONNECT TO ELECTRICAL POWER
To gain access to the transformer/power cord
assemblg, remove the salt hole cover from the
softener. Unclip the tabs on the rear of the top cover
and rotate the cover upward to remove. DO NOT
PULL OR DISCONNECT WIRING.
The softener works on 24 volt-60Hz electric
power. The included transformer changes
standard !20-volt AC house power to 24 volts.
Plug the transformer into a 120-volt outlet onlg.
Be sure the outlet is alwags live so it can not be
switched off bg mistake.
Replace the top cover.
Replace the salt hole cover.
PROGRAMMING THE CONTROL
PROGRAMMING THE CONTROL
CONTROL SETTINGS REQUIRED upon installation
and after an extended power outage.
NOTES:
WHEN THE TRANSFORMER IS PLUGGED INTO THE
ELECTRICALOUTLET, 12:00 PM (flashing),and
PRESENT TIME is displaged. Program the control
as instructed below.
If -_ - - - ,s flashing, use the UP button to
set the correct model code as follows: F30 for
GXSF30H. If gou pass bg the correct code number,
use the DOWN button. Then press the MODE
button to accept the correct model.
A "beep" sounds while pressing buttons for control
programming. One beep signals a change in the
control displag. Repeated beeps mean the control
will not accept a change from the button gou have
pressed, and gou should select another button.
To program the control, gou will use the UP •,
DOWN and MODE buttons.
Use the MODE button to select the desired control
function.
10
SET PRESENT TIME OF DAY
,
,
Press the MODE button until
PRESENTTIME appears in the
displag.
Press UP or DOWN
button to set. The UP button
advances the time; the DOWN
button moves the time in
reverse.
1.1 tl
n.DO
PRESENT _ME
I I 1.3C A_
L PRESENT TIME
,
If the present time is between noon and midnight,
be sure PMshows in the displag. If the present
time is between midnight and noon, be sure AM
shows in the displag.
NOTE: Each press of an UP or DOWN button
changes the time bg one minute. Holding the
button changes the time at a rapid rate.
When the present time is correct, press MODE to
accept.
SET WATER HARDNESS NUMBER
1. Press the MODE button until
HARDNESS appears in the CIS
displag.
HARDNESS
2. Press UP or DOWN button
to set gour water hardness number in the
displag. DOWN decreases the hardness value.
UP increases the hardness value.
NOTE: Each press of a button changes the displag
bg 1, between 1 and 25. Above 25, the displag
changes 5 at a time (25, 30, 35, etc.). Holding a
button in changes the numbers at a rapid rate.
Loading ...
Loading ...
Loading ...