INSTALLATION OPTIONS
Read this entire manual before you install and use your pellet stove. Failure to follow instructions may result
in property damage, bodily injury, or even death! See specic installation details for clearances and other
installation requirements.
Freestanding Unit - supported by pedestal/legs and placed on a non-combustible oor surface in compliance
with clearance requirements for a freestanding stove installation.
Alcove Unit - supported by pedestal/legs and placed on a non-combustible oor surface in compliance with
clearance requirements for an alcove installation.
Your pellet stove may be installed to code in either a conventional or mobile home (see “Special Mobile Home
Requirements”). It is recommended that only a authorized technician install your pellet stove, preferably an
NFI certied specialist. DO NOT CONNECT THIS UNIT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM. The use of other
components other than stated herein could cause bodily harm, heater damage, and void your warranty.
IMPROPER INSTALLATION: The manufacturer will not be held responsible for damage caused by the malfunction
of a stove due to improper venting or installation. Call (800) 750-2723 and/or consult a professional installer if
you have any questions.
Installation
CLEARANCES
Your pellet stove has been tested and listed for installation
in residential, mobile home, and alcove applications in
accordance with the clearances provided in this manual. For
safety reasons, please adhere to the installation clearances and
restrictions. Any reduction in clearance to combustibles may
only be done by means approved by a regulatory authority.
FLOOR PROTECTION
This heater must have a non-combustible oor protector (ember
protection) installed beneath it if the oor is of combustible
material. If a oor pad is used, it should be UL listed or equal. The
oor pad or non-combustible surface should be large enough
to cover at least the area under the product and 6” (152 mm)
beyond the front and beyond each side of the fuel loading
and ash removal openings. Floor protection must extend under
and 2” (51 mm) to each side of the chimney tee for an interior
vertical installation.
Canadian Installations require a minimum of 450 mm [17.7”]
beyond the front of the unit and 200 mm [7.8”] beyond each
side of the unit. A Floor Protector of 1/4” thick is recommended
for this installation.
SIDEWALL CLEARANCES PARALLEL INSTALLATION
SIDEWALL CLEARANCES CORNER INSTALLATION
in mm
PARALLEL
A Backwall to unit 8 203
B Sidewall to ue 12.5 317
C Sidewall to top edge of unit 8 203
CORNER D Adjacent wall to unit 3 76
ALCOVE
E Alcove depth 36 914
F Alcove height 60 1524
G Backwall to Flue 2 50
FLOOR
PROTECTOR
H Rear 1 25
J Front 6 152
K Side 6 152
FLOOR PROTECTOR
H
K K
J
D
D
D
D
B
A
G
C
B
C
BACK WALL
SIDEWALL
BACK WALL
SIDEWALL
E
F