Before you call for service...
Troubleshooting Tips
Problem Possible Causes What To Do
Salty tasting or Unit not sanitized * Complete theSanitization Procedureson page 12.
brown/yellow colored • At completion of recharge cucle (approx.2 hrs),run water
water after installation from faucets to purge the salty water.
Lowwater pressure Checkpressure.
• Drainheight 8' or less,pressureshouldbe minimum of 20 psi.
• Drainheight above8',pressureshouldbe minimum of 50 psi.
Restricted drain hose • Cleanand reconnect hose.
• Checkfor kinksin drain line.
Brown/yellow Unit was idle for a period of time • Complete theSonitizotion Procedureson page 12.
colored water
Resinbeads showing Cracked distributor • Callfor service,
up in drinking water
and sink
Soundsgou might hear Running water from the unit • Thisisnormal.
into a drain during recharge
Water has air bubbles Air in sgstem after installation • Will go away after it runs for a while.
and is cloudy
Error Codeon control Wiring mag have worked loose • Seepage 16for details.
in the control
• Unplug transformer,
• Removecontrol cover,releaseclips on side.
• Checkfor loose/incorrect wiring connections to electronic
board or switch. Reconnect asrequired.
• Reassemblecontrol cover.
• Plugin Transformer,
• Wait six minutes for Error Codeto reappear,
• If Error Codereappears,call for service.