KitchenAid KXU4236YSS0 30" & 36" professional hood

User Manual - Page 12

For KXU4236YSS0.

PDF File Manual, 36 pages, Download pdf file

Loading ...
Loading ...
Loading ...
Make Electrical Connection
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Disconnect power.
2=
E
C
L
A. White wires
B. Black wires
C. UL fisted wire connectors
D. Green (or bare) and yellow-green ground wire
E. Home power supply cable
F. UL fisted or CSA approved V2"strain relief
Use UL listed wire connectors and connect the black wires
(B) together.
3. Use UL listed wire connectors and connect the white wires
(A) together.
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
4. Connect green (or bare) ground wire from home power supply
to the yellow-green ground wire (D) in the terminal box using
UL listed wire connector.
5. Install terminal box cover.
6. Reinstall the rear support.
7. Reinstall the 2 lateral supports.
8. Check that all light bulbs are secure in their sockets.
9. Reconnect power.
For Vented Installations Only:
Connect ventwork to hood. Seal joints with clamps to
make secure and airtight.
Cornplete Installat on
1. Replace grease filters. See the "Range Hood Care" section.
2. Check the operation of the range hood fan and light. See
"Range Hood Use" section.
If range hood does not operate, check to see whether a
circuit breaker has tripped or a household fuse has blown.
Disconnect power and check wiring connections.
NOTE: To get the most efficient use from your new range hood,
read the "Range Hood Use" section.