Loading ...
Loading ...
Loading ...
English
English 3
Indoor Unit Installation Drawings
Before screwing the remote
controller holder to the wall,
make sure that control
signals are properly
received by indoor unit.
E
Remote
controller holder
Fixing screw for remote
controller holder
1/8” × 13/16” (M3 × 20mm)
F
D
Wireless
remote
controller
Service lid
Opening service lid
Service lid is opening/closing type.
Opening method
1)
Remove the service lid screw.
2) Pull out the service lid diagonally
down in the direction of the arrow.
3)
Pull down.
1-3/16” (30mm)
or more from ceiling
Front panel
1-15/16” (50mm)
or more from walls
(on both sides)
Titanium apatite photocatalytic
air purifying filter (2 pcs)
A Mounting plate
C
Air filters
Mounting plate fixing screw
3/16” × 1” (M4 × 25mm)
B
3/16” × 5/8”
(M4 × 16mm)
INTELLIGENT EYE
sensor
Titanium apatite
photocatalytic
air-purifying filter
Filter frame
Air filter
Ta b
Wrap the thermal insulation
pipe with the finishing tape
from bottom to top.
Cut thermal insulation
pipe to an appropriate
length and wrap it with
tape, making sure that no
gap is left in the insulation
pipe’s cut line.
Caulk
pipe hole
gap
with putty.
The mounting plate
should be installed on a
wall which can support the
weight of the indoor unit.
How to attach the indoor unit
Hook the claws of the bottom frame
to the mounting plate.
If the claws are difficult to hook,
remove the front grille.
How to remove the indoor unit
Push up the marked area (at the
lower part of the front grille) to
release the claws. If it is difficult to
release, remove the front grille.
Front grille
A
Mounting
plate
Clip
Bottom
frame
Mark (rear side)
INTELLIGENT EYE sensor
CAUTION
•DonothitorforcefullypushtheINTELLIGENTEYEsensor.Thiscanleadtodamageandmalfunction.
•Donotplacelargeobjectsnearthesensor.Alsokeepheatingunitsorhumidiersoutsidethesensor’sdetectionarea.
01_EN_3P297301-1.indd 3 10/20/2011 2:38:22 PM
Loading ...
Loading ...
Loading ...