Viking DIL900 900 CFM In-Line Ventilator Kit

Installation Instructions - Page 2

For DIL900. Also, The document are for others Viking models: VCWH*, VCIH*, DBCV*, DICV*, DCWH*, DCWL*, DCWN*, DTWS*, DSWB*

PDF File Manual, 4 pages, Read Online | Download pdf file

DIL900 photo
Loading ...
PLANNING THE INSTALLATION
1.
Locate the inline fan so that the length of the duct run and
number of elbows needed is kept to a minimum.
2.
The inline fan is designed for use with 10 diameter duct.
3. Use rigid metal ductwork.
4. Always install ventilation products with an approved wall
or roof cap.
5.
For a truly quiet kitchen ventilation system add a Viking
Inline Duct Silencer part number VSIL10 (sold separately)
to the installation. The simple addition of a inline duct si-
lencer between the range hood and the DIL900 fan can
typically reduce the perceived sound level of the system by
more than 50%.
MOUNTING THE DIL900 INLINE FAN
To minimize any potential vibration noise it is recommended
that the inline fan be mounted with
Viking Vibration Isolation
Kit part number
ILVK
(sold separately)
ILVK (sold separately)ILVK
.
Various mounting methods are shown below.
2
MODEL
A
B
C
D
E
Weight
DIL900
†10
1
12
¹⁄
¹⁄¹⁄
12
¹⁄
¹⁄¹⁄
7
15
lbs.

All dimensions in inches.
† Duct connections ar
e
¹
⁄₈
¹
⁄₈ ¹
smaller than the duct
si
ze.
Vertical Installation
with out Kit
Vertical Installation
with Kit
Horizontal
Installation
with Kit
Horizontal
Installation
with out Kit
Loading ...