Special provisions for mobile home installations
The exhaust vent must be securely fastened to a noncombustible portion of the mobile home
structure and must not terminate beneath the mobile home. Terminate the exhaust vent
outside.
/I
m
Determine vent path
Select the route that will provide the straightest and most direct path outdoors.
Plan the installation to use the fewest number of elbows and turns.
When using elbows or making turns, allow as much room as possible.
Bend vent gradually to avoid kinking.
Use the fewest 90 ° turns possible.
Determine vent length and elbows needed for best drying performance
Use the following Vent system chart to determine type of vent material and hood
combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified in the Vent system chart.
Exhaust systems longer than those specified will:
Shorten the life of the dryer.
Reduce performance, resulting in longer drying times and increased energy usage.
The Vent system chart provides venting requirements that will help to achieve the best drying
performance.
Vent system chart
NOTE: Performance of rear exhaust to either side of the dryer is equivalent to adding one
elbow. To determine maximum exhaust length, add one elbow to the chart.
NOTE: Bottom exhaust performance is equivalent to adding two elbows. To determine
maximum exhaust length, add one elbow to the chart.
Number of Type of Box or Angled
90 ° turns vent Louvered hoods
or elbows hoods
0 Rigid metal 100 ft (30.5 m) 94 ft (28.7 m)
Flexible metal 72 ft (21.9 m) 64 ft (19.5 m)
1 Rigid metal 90 ft (27.4 m) 84 ft (25.6 m)
Flexible metal 67 ft (20.4 m) 59 ft (18 m)
2 Rigid metal 80 ft (24.4 m) 74 ft (22.6 m)
Flexible metal 63 ft (19.2 m) 55 ft (16.8 m)
3 Rigid metal 71 ft (21.6 m) 65 ft (19.8 m)
Flexible metal 61 ft (18.6 m) 53 ft (16.2 m)
4 Rigid metal 63 ft (19.2 m) 57 ft (1 7.4 m)
Flexible metal 59 ft (18 m) 51 ft (15.5 m)
1.
2.
3.
1.
Install exhaust hood. Use caulking compound to seal exterior wall opening around
exhaust hood.
Connect vent to exhaust hood. Vent must fit inside exhaust hood. Secure vent to exhaust
hood with 4" (10.2 cm) clamp.
Run vent to dryer location. Use the straightest path possible. See "Determine vent path" in
"Plan Vent System." Avoid 90 ° turns. Use clamps to seal all joints. Do not use duct tape,
screws or other fastening devices that extend into the interior of the vent to secure vent.
Excessive Weight Hazard
Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.
To protect the floor, use a large, flat piece of cardboard from the dryer carton. Place
cardboard under the entire back edge of the dryer.