GE - General Electric AZ55H07DABM1 GE zoneline air conditioner

User Manual - Page 19

For AZ55H07DABM1.

PDF File Manual, 24 pages, Download pdf file

Loading ...
Loading ...
Loading ...
Before YouCallForService... .CUppliances.com
Troubleshooting -tips
Problem Possible Causes What ToDo
Zoneline does The mlit is * Make sure the Zoneline plug is pushed colnpletelv
notstart unplugged, into the outlet.
The fuse is blown/dreuit * Check the house filse/circuit breaker box and replace
breaker is tripped, the filse or reset the breakei:
The unit is waiting for This is hernial. The Zoneline will start again after
the compressor overload it resets.
protector to reset,
Power failure,
Zoneline does not cool
or heat as it should
Indoor airflow
is restricted.
Outdoor airflow is
restricted or recirculated.
The temp control may
not be set high enough.
The air filter is dirty,
The room may have
been hot or cold.
Outdoor air is
entering the room.
If power tifilure occmg, set the mode control to STOP.
When power is restored, set the mode control to the
desired setting.
There is a protective time delay (up to 3 nfinutes) to
prevent tripping ot the colnpressor overload. For this
reason, the unit 1nay not start iloimal heating or cooling
fi)I" 3 ininutes atter it is turned back on.
Make sure there are I1O cm'tains, blinds or flu'nimx'e
blocking the fl'ont of the Zoneline.
Make sure the rear grille is not x'estricted. This can cause
the unit to cycle off due to the compressor overload.
Outdoor grille 1//ust ha\e a nfininnun of 65% fl'ee area.
Non-GE grilles Inay be too restrictive tor proper
perfi)mlance. Consult your salespei_on fiw assistance.
Turn the control to a lower oi" higher setting.
NOTE:Thetemperaturebmitermaybe bmitlWthe temperaturerange.
Clean the filter at least e\'eI y 30 days.
See the Operating Instructions section.
When the Zoneline is fii_t turned Oll wm need to
allow/line fi)r the rooln to cool down or warm alp.
Set the vent control to the CtOSEposition.
Burning odoratthe start Dust is on the surface This can cause a "burning" odor at the beginning of
of heating operation of the heating element, the heating operation. This odor should quickly lade.
The air is not always The heat pmnp is not This is hernial. The heat pump will produce wmm air
cool or hot during producing hot air, but not as hot as air produced when the highei_cost
operation electric heat is used.
The fma switch may be This causes the fan to blow I"OOlll tenlperature air
set at continuous fan even when the colnpressor or heater cycles off.
The continuous air lnovenlent provides better
overall telnperature control,
The air does not feel The heat pump alone Use the Electric Heat Option. This turns off the
warm enough during produces air that feels heat pump and warms with electric heat only.
heating operation cooler thmz desired. NOTE: Use of this option will result in increased energy
consumption.
Temperaturedisplay The compressor may
flashes have failed,
Set the Inode control to STOP and then restart the
unit. If the flashing light reappears within 30 nfinutes,
call tor service.
/9