Installation
6 Install the Light Bulbs
To prevent possible OVERHEATING of the end panel or light socket:
Use ONLY A19 light bulbs.
DO NOT use incandescent bulbs larger than 100W.
DO NOT use compact fluorescent light bulbs larger than 26W (100W equivalent).
DO NOT use halogen bulbs.
DO NOT use short neck or specialty light bulbs.
LED bulbs may cause remote control radio interference. Use ONLY LED bulbs recommended
here: chamberlain.com/bulb.
1. Pull light lens down.
2. Insert light bulb.
3. Close light lens.
MODELS 8160W AND 8160WB
or
MODELS 8155W, 8164W, and 8165W
100 Watt (Max)
Standard Light Bulb
Release Tab
Lens Hinge
7 Attach the Emergency Release Rope and Handle
To prevent possible SERIOUS INJURY or DEATH from a falling garage door:
If possible, use emergency release handle to disengage trolley ONLY when garage door
is CLOSED. Weak or broken springs or unbalanced door could result in an open door
falling rapidly and/or unexpectedly.
NEVER use emergency release handle unless garage doorway is clear of persons and
obstructions.
NEVER use handle to pull door open or closed. If rope knot becomes untied, you could
fall.
1. Insert one end of the emergency release rope through the handle. Make sure that “NOTICE”
is right side up. Secure with an overhand knot at least 1" (2.5 cm) from the end of the rope
to prevent slipping.
2. Insert the other end of the emergency release rope through the hole in the trolley release
arm. Mount the emergency release within reach, but at least 6 feet (1.83m) above floor,
avoiding contact with vehicles to prevent accidental release and secure with an overhand
knot.
NOTE: If it is necessary to cut the emergency release rope, seal the cut end with a match or lighter to
prevent unraveling. Ensure the emergency release rope and handle are above the top of all vehicles
to avoid entanglement.
Trolley
Release Arm
FOR T-RAIL