Warranty Safety CleaningOperation Installation Service Parts
1. Determine whether hood will discharge vertically
(3¼” x 10” or 7” Round) or horizontally (3¼” x 10”
only).
2. Run ductwork between the hood location and a roof
cap or wall cap.
3. Choose a straight, short duct run to allow the hood to
perform most e ciently. Long duct runs, elbows and
transitions will reduce the performance of the hood.
Use as few of them as possible. When possible, use
at least 2 foot straight runs before any turns. Larger
ductwork may be required for best performance with
longer duct runs.
4. Install wall cap or roof cap (sold separately). Connect
metal ductwork to cap and work back towards the
hood location. Use 2” metal foil duct tape to seal the
joints between ductwork sections.
INSTALL DUCTWORK (DUCTED INSTALLATION ONLY)
NOTE: Distances over 24” are at the installer and user
discretion.
1. If present, remove all protective poly lm from the
hood and/or parts. Using the tab, remove the
Aluminum Mesh Filters from the hood by pulling
down the tab and tilting lters out.
PREPARE THE HOOD
DAMPER
ASSEMBLY
SCREWS
EZ1
BRACKETS
2. Remove the EZ1 brackets from inside the hood by
cutting o the tie wrap. Remove both screws holding
damper assembly to hood. Remove parts bag
(captured behind the damper assembly). Remove
damper assembly from inside the hood and keep
the screws for further use.
3. Remove the wiring cover (shaded part on illustration
beside) by sliding it out from the hood and set it
aside.
Loading ...
Loading ...
Loading ...