installation Checklist
Water Heater Location
Centrally located with the water piping system.
Located as close to the gas piping and vent pipe
system as possible.
,, Located indoors and in a vertical position.
Protected from freezing temperatures.
,, Proper clearances from combustible surfaces
maintained and not installed directly on a carpeted
floor.
Provisions made to protect the area from water
damage. Drain pan installed and piped to an
adequate drain.
Installation area free of corrosive elements and
flammable materials.
Sufficient room to service the water heater.
Water heater not located near an air moving device.
Combustion Air Supply and Ventilation
,, Sufficient fresh air supply for proper water heater
operation.
Fresh air not taken from areas that contain negative
pressure producing devices such as exhaust fans,
fireplaces, etc.
Fresh air supply free of corrosive elements and
flammable vapors.
Fresh air openings sized correctly with
consideration given to the blocking effect of louvers
and grilles.
Ductwork is the same cross-sectional area as the
openings.
Vent Pipe System
Drafthood properly installed.
Vent connectors securely fastened with screws and
supported properly to maintain 6 inch clearance.
,, Vent connector made of approved material and
sized correctly.
,, Vent pipe system in accordance to all local and
state codes or in absence of local and state codes
with the "National Fuel Gas Code", NFPA54, ANSI
Z223.1-1atest edition.
!1
o
Flue baffle engaged in slots provided in the flue
tube.
Flue way, drafthood or vent pipe system not
obstructed in any way.
Water System Piping
,, Temperature and pressure relief valve properly
installed with a discharge line run to an open drain
and protected from freezing.
All piping properly installed and free of leaks.
Heater completely filled with water.
Closed system pressure build-up precautions
installed.
Tempering valve installed per manufacturer's
instructions.
Gas Supply and Piping
Gas supply is the same type as listed on the water
heater data plate.
,, Gas line equipped with shut-off valve, union and
drip leg.
Approved pipe joint compound used.
,, Adequate pipe size and of approved material.
,, Chloride-free soap and water solution or other
approved means used to check all connections and
fittings for possible gas leaks.