Loading ...
Loading ...
Loading ...
26
BURNERS
These parts can be removed and cleaned with appropriate products.
After cleaning, the burners and their ame spreaders must be well dried and correctly
replaced.
Check that the electrode/s “S” (gs. 15a, 15c, 15d, 15e) next to each burner is/are
always clean to ensure trouble-free sparking.
Check that the probe/s “T” (gs. 15a, 15c, 15d, 15e) next to each burner is/are always
clean to ensure correct operation of the safety valves.
Both the probe and ignition plug must be very carefully cleaned.
Note: To avoid damage to the electric ignition do not use it when the burners are
not in place.
CORRECT REPLACEMENT OF THE AUXILIARY, SEMI-RAPID AND RAPID
BURNER (the rapid burner is available for the models DEGHSL75, DEGHSL90
only)
It is very important to check that the burner ame spreader F” and the cap “C” have been
correctly positioned (see gs. 15a and 15b). Failure to do so can cause serious problems.
They shall be level and the ame spreader must not rotate.
CORRECT REPLACEMENT OF THE TRIPLE-RING COMPACT (model
DEGHSL60 only), TRIPLE-RING (model DEGHSL75 only) AND DUAL
BURNER (model DEGHSL90 only)
It is very important to check that the burner ame spreader “F1”, “F2” or “F3” and the caps
A”, “B” have been correctly positioned (see gs. 15c, 15d, 15e, 15f, 15g). Failure to do so
can cause serious problems.
Fit the ame spreader to the housing: the burner ribs must be tted in their housing as
shown by the arrows (see gs. 15c, 15d or 15e).
Then position the cap “A” and the ring “B” (see g. 15f).
They shall be level and the ame spreader must not rotate (see g. 15g).
S
F
C
T
Figure 15a Figure 15b
Loading ...
Loading ...
Loading ...