3 ANOTHER ELECTRIC COMPONENTS
• Cooling is impossible
Compressor _._ Check if current flows to
doesn't run. _ the following
components.
Cause.
a. Thermistor
b. Starting devices
c. OLP
d. Compressor coil
e. Circuit Parts
_- Poor contacting.
Shorted or broken.
_, Poor contacting
or shorted.
Coil shorted.
Poor contacting
or shorted.
Replace
each component.
Running state of
Compressor is poor.
• Cooling ability is poor
t
] F
Check a starting
voltage.
J "-L
Check if current flows ] ,.j
to starting devices.
Check current flowing
in sub-coil of
Compressor.
Check capacity of OLR ]_{
The items described ]_[
above are normal.
Low voltage.
Poor contacting _,[
and broken.
Shorted.
Lack of capacity.
Coil of motor _[
Compressor.
Raise the voltage.
Replace
each component.
Replace
the compressor.
Replace
each component.
Fan motor
doesn't run.
Much frost are sticked
to the EVAPORATOR.
[__ Check current flowing
in SWITCH, DOOR. "[
Checkcurrentflowinginthe
MOTOR[MECH],FAN. _
Check current flowing
of the following
components.
• THERMISTOR
• FUSE, MELTING
Check current flowing
of the following
components.
• HEATER, SHEATH
Poor contacting.
Coil is shorted.
Shorted. _[
Replace
each component.
Replace
the Heater, Sheath
-13-