page 4
4. Installation of Wall Bracket. (cont.)
wall
bracket
Attach wires from 4-wire plug to the supply wires
(from the wall) as follows:
Connect GREEN wire from 4-wire plug to GREEN/BARE
wire from wall with wire connector provided.
Connect BLACK wire from 4-wire plug to BLACK wire
from wall with wire connector provided. Connect WHITE
wire from 4-wire plug to WHITE wire from wall with wire
connector provied. Connect BLUE wire from 4-wire plug
to BLUE wire from wall with wire connector provided.
stud
stud
1/4"
(6.5mm)
mounting
hole
pilot holes
7 feet
(2.13m)
First determine the approximate position of where you
want the fan to be located on the wall. [Remember that
the fan must be mounted at least 7 feet (2.13m) from the
floor.]
NOTE: Ensure there is an electrical source near the
approximate location, such as an existing outlet box
or an electrical outlet, as you will need to pull the
supply wires through the opening in the middle of the
wall bracket.
You MUST use ALL FOUR holes in wall bracket when
installing wall bracket. Position wall bracket on wood
stud or wood post and mark 4 hole locations.
Drill 4 pilot holes over holes marked onto mounting
surface. Position wall bracket over pilot holes and install
screws (provided in hardware pack) into each hole.
ALTERNATE CONCRETE WALL INSTALLATION: Use all 4
mounting 1/4" (6.5mm) holes when installing wall bracket
on a concrete wall. The 3/16 in. (5mm) concrete wall
anchors necessary for this type of installation are NOT
provided and must be purchased separately. Make sure
that concrete wall anchors can support a total of 80
lbs.
WARNING: It is very important you use the proper
hardware when installing the wall bracket as this will
support the fan.
screws
screws
Make sure all electrical connections comply with Local
Codes or Ordinances and the National Electrical Code (or
the Canadian Electric Code). If you are unfamiliar with
electrical wiring or if the house/building wires are different
colors than those referred to below, please use a qualified
electrician.
WARNING: If using this fan in a DAMP location, this fan
must be connected to a supply circuit that is protected
by a Ground Fault Circuit Interrupter (GFCI) to reduce
the risk of personal injury, electrical shock or death.
5. Wiring.
4-wire
plug
WHITE
BLACK
BLACK
BLUE BLUE
WHITE
wire
connector
W
GREEN
GREEN