GE - General Electric TPS24BPDABS GE refrigerator - d series

User Manual - Page 34

For TPS24BPDABS.

PDF File Manual, 108 pages, Download pdf file

Loading ...
Loading ...
Loading ...
Performance Data Sheet
GE
Water by Culligan Filtration System
FXRC Cartridge
Health Claim Performance Certified by NSF/ANSI*
700% safety factors built in for unmetered usage)
Standard No. 42: Aesthetic Effects
Parameter
Chlorine
T&O
Particulate** 99.98
Standard No. 53: Health Effects
USEPA
MCL
USEPA
MCL
1 NTU***
99.95% Reduction
15 ppb
15 ppb
Parameter
Turbidity
Cysts
Lead at pH 6.5
Lead at pH 8.5
Influent
Challenge
2.06 ppm
3,100,064
Effluent
Average
0.14 ppm
519
Influent
Challenge
23.25 NTU
494,169
157ppb
162 ppb
Effluent
Average
0.10 NTU
92
3 ppb
3 ppb
Maximum
0.3 ppm
2425
Maximum
0.17 NTU
179
3 ppb
3 ppb
% Reduction
Average
93
Minimum
85
99.92
Minimum
99.3
99.96
>98
>98
%Reduction
Average
99.6
99.98
>98
>98
* Tested ushTga flow rate of 0.5gpm; pressure of 60 psig; pH of Z5 +_0.5; temp. of 20° +_2.5°C.
_xMeasurement h7Particles/ml
_ NTU=Nephelometric Turbidity units
Operating Specifications
Capa(ity: (ertitied for up to 200 gallons (757 I.)
:_ Pressure requirement: 40-120 psi (2.8-8.2 bar), non-shock
Temperature: 33°-100 ° F. (0.6°-38 ° C.)
:_Flow rate: 0.5 gpm (1.9 Lpm)
General Installation/Operation/Maintenance Requirements
Flush new cartridge at tUII flow tin 60 seconds to purge out trapped air.
:, Replace cartridge when flow becomes too slow; at least every six months.
Special Notices
Installation instructions, parts and service awailability, and standard warranty are included with the product when shipped.
:,This drinking water system must be maintained according to manutacmrer's instructions, including replacement offiher
cartridges.
:, Do not use where the water is microbiologically unsate, or with waters of unknown quality without adequate disinti_ction
beti)re or after the system; system may be used on disinfected water that may contain filterable cysts.
The contaminants or other substances removed or reduced by this water treatment system are not necessarily in your water.
:, Check ti)r compliance with the state and local laws and regulations.
NSF International Standards
Standard No. 42: Aesthetic Effects
Chemical Unit
Taste and Odor Redu(fion
Chlorine Re(hmdon, Class I
Mechanical Filuation U nit
Particulate Reducdon, (lass I
Tested& Certified
to ANSI/NSF
Standards42 & 53
Standard No. 53: Health Effects
Chemical Re&action Unit
I+ead Reduction
Mechanical Fihraoon Unit
Cyst Re(h_cfion
Turbidi/y Re(h_ction
The Water by Culligan Fihration System and FXRC cmuidge have been
tested and Certified by NSF only ti)r the fimctions listed immediately ab_)ve.
Made by: Culligan International, Westmont, IL 60559, T: (630) 654-4000
General Electric, Appliance Prok, Louisville, KY 40225 _) 1997 GE